Influencia de la pupila en la calidad visual con LIO multifocales rotacionalmente asimétricas con segmento de cerca integrado en la superficie

Título original: Pupil influence on the quality of vision in rotationally asymmetric multifocal IOLs with surface-embedded near segment

Emmanuel Eric Pazo, Richard N. McNeely, Olivier Richoz, Andrew M. Nesbit, Tara Moore, Jonathan Edward Moore

Journal of Cataract & Refractive Surgery, 2017 · artículo · doi:10.1016/j.jcrs.2017.08.013 · citado 20 veces

Cataratas y cirugía del segmento anterior

Resumen visual. Serie de casos comparativa retrospectiva · 180 ojos. Seguimiento: 18 months. Las pupilas preoperatorias pequeñas reducen la calidad visual con una LIO multifocal rotacionalmente asimétrica.
Resumen visual: SVG · PNG · JSON · reutilización libre citando la fuente (CC BY 4.0)

De un vistazo

Las pupilas preoperatorias pequeñas reducen la calidad visual con una LIO multifocal rotacionalmente asimétrica.

Diseño
Serie de casos comparativa retrospectiva
Muestra
180 ojos
Seguimiento
18 months

Resumen

Este resumen se muestra en su idioma original, el inglés, porque el artículo no tiene una licencia abierta que permita traducciones.

PURPOSE: To evaluate the influences of preoperative pupil parameters on the visual outcomes of the SBL-3, a rotationally asymmetric multifocal intraocular lens (IOL) with a surface-embedded near segment. SETTING: Cathedral Eye Clinic, Belfast, Northern Ireland, United Kingdom. DESIGN: Retrospective comparative case series. METHODS: Postoperatively, patients divided into 4 groups according to their pupil size as follows: Group A: 2.50 to 2.99 mm, Group B: 3.00 to 3.50 mm, Group C: 3.51 to 4.00 mm, and Group D: 4.01 to 4.50 mm. The uncorrected distance (UDVA), intermediate (UIVA), and near (UNVA) visual acuities, IOL centration and tilt, and quality of vision (QoV) questionnaires were compared between the 4 groups for 18 months postoperatively. RESULTS: The study comprised 90 patients (180 eyes). The mean preoperative pupil (photopic and mesopic) diameter was 4.3 mm ± 0.3 (SD) and 5.6 ± 1.4 mm, respectively, which decreased to 3.8 ± 0.7 mm and 4.9 ± 1.2 mm, respectively, at 18 months. Eighteen months postoperatively, both photopic and mesopic pupil groups had a statistically significant reduction in size from preoperative levels. No significant differences in UDVA, UIVA, and UNVA were found between the groups (P > .001). Significant differences in the QoV questionnaire day scores and night scores were found between the 4 groups (P < .001). CONCLUSIONS: The rotationally asymmetric multifocal IOL provided excellent optical performance during 18-months follow-up. The preoperative photopic pupil is an important parameter for consideration of this type of IOL because smaller pupils have a significant negative subjective impact on QoV.

Palabras clave: pupil size; visual quality; visual acuity; cataract surgery outcomes

Acceso

Cómo citar

Pazo, E. E., McNeely, R. N., Richoz, O., Nesbit, A. M., Moore, T., Moore, J. E. (2017). Pupil influence on the quality of vision in rotationally asymmetric multifocal IOLs with surface-embedded near segment. Journal of Cataract & Refractive Surgery. https://doi.org/10.1016/j.jcrs.2017.08.013

Mostrar BibTeX
@article{pazo2017pupil,
  title = {{Pupil influence on the quality of vision in rotationally asymmetric multifocal IOLs with surface-embedded near segment}},
  author = {Pazo, Emmanuel Eric and McNeely, Richard N. and Richoz, Olivier and Nesbit, Andrew M. and Moore, Tara and Moore, Jonathan Edward},
  journal = {Journal of Cataract & Refractive Surgery},
  year = {2017},
  doi = {10.1016/j.jcrs.2017.08.013},
  url = {https://doi.org/10.1016/j.jcrs.2017.08.013},
}