Adherencia al seguimiento a largo plazo tras el implante de lente de colámero implantable en pacientes con miopía alta: un estudio unicéntrico de cohorte retrospectiva y encuesta CAP
Título original: Long-term follow-up adherence after implantable collamer lens implantation in high-myopia patients: a single-center retrospective cohort and KAP survey study
Tongxin Niu, Xin Li, Ying Liu, Xin Li, Jingran Cao, Emmanuel Eric Pazo, S Z Zhao, Zhe Jia, Ruibo Yang
Miopía y errores refractivosCataratas y cirugía del segmento anterior
De un vistazo
El seguimiento tras la cirugía ICL por miopía alta cae drásticamente, con riesgo de detectar tarde el glaucoma y las complicaciones retinianas.
- Diseño
- Cohorte retrospectiva y encuesta CAP
- Muestra
- 2,393 pacientes
- Asistencia después de 4 años
- <15%
- Asistencia al seguimiento a los 9 años
- 3%
- Glaucoma normotensivo detectado
- 2.34%
Resumen
Resumen Antecedentes La miopía alta conlleva riesgo de complicaciones que amenazan la visión, como glaucoma, degeneración retiniana y roturas retinianas periféricas. Aunque la cirugía de implante de lente intraocular fáquica (LIOF) corrige eficazmente el error refractivo y proporciona buenos resultados visuales, no reduce los riesgos oculares asociados a la miopía alta. Por ello, el seguimiento regular a largo plazo sigue siendo importante para detectar a tiempo las complicaciones relacionadas con la miopía alta en estos pacientes. Métodos Este estudio de métodos mixtos incluyó a 2,393 pacientes con miopía alta a los que se implantó una lente de colámero implantable (ICL) V4c entre 2016 y 2023 en un único centro terciario. Se analizaron las tendencias de asistencia al seguimiento a largo plazo en un subgrupo de 133 pacientes con registros longitudinales de seguimiento disponibles. En otro subgrupo de 128 pacientes con más de 1 año de seguimiento completado se evaluaron las complicaciones oculares detectadas. Se realizó una encuesta transversal de Conocimientos, Actitudes y Prácticas (CAP) entre los pacientes operados. De 1,064 cuestionarios distribuidos, se incluyeron en el análisis 174 respuestas válidas. Se realizó una regresión logística para identificar los factores asociados a la adherencia al seguimiento. Resultados La asistencia al seguimiento a largo plazo disminuyó progresivamente con el tiempo, con tasas inferiores al 15% después de cuatro años y del 3% a los nueve años. Se recogieron y analizaron 174 cuestionarios CAP válidos, con una tasa de respuesta válida del 16.35% (se distribuyeron 1,064 cuestionarios). Las principales barreras fueron la falta de conciencia sobre la salud ocular, la ausencia de síntomas y el acceso limitado a la atención de seguimiento. Durante las exploraciones de seguimiento posoperatorias se detectaron complicaciones oculares, como glaucoma normotensivo (2.34%) y lesiones retinianas asociadas a la miopía alta (3.13%). Cabe destacar que todos los casos confirmados de glaucoma se produjeron en pacientes de ≥ 40 años. En los pacientes con miopía alta, una presión intraocular normal, una agudeza visual central normal, una morfología atípica del disco óptico, la atrofia peripapilar miópica y una retina más delgada pueden contribuir a una detección tardía. La regresión logística mostró que un mejor conocimiento y una actitud positiva hacia el seguimiento eran factores protectores independientes de la adherencia. Conclusiones Un seguimiento deficiente a largo plazo tras el implante de ICL puede retrasar la detección de las complicaciones oculares relacionadas con la miopía alta. Se necesitan con urgencia educación sanitaria específica, un seguimiento estratificado por riesgo para los subgrupos de mediana edad y con miopía alta y un mejor acceso a la atención para mejorar la detección precoz y prevenir la pérdida visual irreversible en estos pacientes.
Traducido del resumen original en inglés (licencia: CC BY).
Mostrar el resumen original
Abstract Background High myopia carries the risk of sight-threatening complications, including glaucoma, retinal degeneration, and peripheral retinal breaks. Although phakic intraocular lens (PIOL) implantation surgery effectively corrects refractive error and provides good visual outcomes, it does not reduce the ocular risks associated with high myopia. Therefore, regular long-term follow-up remains important for the timely detection of high myopia–related complications in these patients. Methods This mixed-methods study included 2,393 patients with high myopia who underwent V4c implantable collamer lens (ICL) implantation between 2016 and 2023 at a single tertiary center. Long-term follow-up attendance trends were analyzed in a subgroup of 133 patients with available longitudinal follow-up records. A separate subgroup of 128 patients with more than 1 year of completed follow-up was assessed for detected ocular complications. A cross-sectional Knowledge–Attitude–Practice (KAP) survey was conducted among postoperative patients. Of 1,064 distributed questionnaires, 174 valid responses were included in the analysis. Logistic regression was performed to identify factors associated with follow-up adherence. Results Long-term follow-up attendance declined progressively over time, with rates falling below 15% after four years and to 3% by nine years. A total of 174 valid KAP questionnaires were collected and analyzed, with a valid response rate of 16.35% (1,064 questionnaires were distributed). Major barriers included a lack of eye healthcare awareness, absence of symptoms, and limited access to follow-up care. Ocular complications, including normal-tension glaucoma (2.34%) and retinal lesions associated with high myopia (3.13%), were detected during postoperative follow-up examinations. Notably, all confirmed glaucoma cases occurred in patients aged ≥ 40 years. In patients with high myopia, normal intraocular pressure, normal central visual acuity, atypical optic disc morphology, myopic peripapillary atrophy, and a thinner retina may contribute to delayed detection. Logistic regression showed that better knowledge and a positive attitude toward monitoring were independent protective factors for adherence. Conclusions Poor long-term follow-up after ICL implantation may lead to delayed detection of high myopia–related ocular complications. Targeted health education, risk-stratified monitoring for middle-aged and high myopia subgroups, and improved access to care are urgently needed to enhance early detection and prevent irreversible vision loss in these patients.
Palabras clave: implantable collamer lens; high myopia; phakic intraocular lens; normal-tension glaucoma; myopic retinal degeneration; patient education; middle-aged patients; retinal thickness
Acceso
Cómo citar
Mostrar BibTeX
@article{niu2026long,
title = {{Long-term follow-up adherence after implantable collamer lens implantation in high-myopia patients: a single-center retrospective cohort and KAP survey study}},
author = {Niu, Tongxin and Li, Xin and Liu, Ying and Li, Xin and Cao, Jingran and Pazo, Emmanuel Eric and Zhao, S Z and Jia, Zhe and Yang, Ruibo},
journal = {Research Square},
year = {2026},
doi = {10.21203/rs.3.rs-10004973/v1},
url = {https://doi.org/10.21203/rs.3.rs-10004973/v1},
}
Trabajos relacionados
- Predicción de la refracción ciclopléjica basada en aprendizaje automático con el Eyerobo Vision Screener: diseño, un estudio transversal comparativo de dispositivos (2026)
- Características de los parámetros biológicos y selección del tamaño de la lente de colámero implantable (ICL) en ojos con miopía moderada, alta y muy alta (2025)
- Medición automatizada basada en aprendizaje profundo del volumen de retinosquisis y desprendimiento en la miopía patológica con contracción escleral posterior (2026)
- Desarrollo y validación interna de un modelo transformer sensible al tiempo para predecir la progresión de la miopía infantil a partir de datos longitudinales irregulares de cribado escolar (2026)
- Nuevo enfoque para la evaluación cuantitativa del estafiloma escleral: análisis de medidas de curvatura discreta de la esclera (2026)