简体中文

← 论文

瞳孔对表面嵌入式近用区旋转非对称多焦点人工晶状体视觉质量的影响

原文标题: Pupil influence on the quality of vision in rotationally asymmetric multifocal IOLs with surface-embedded near segment

Emmanuel Eric Pazo, Richard N. McNeely, Olivier Richoz, Andrew M. Nesbit, Tara Moore, Jonathan Edward Moore

Journal of Cataract & Refractive Surgery, 2017 · 期刊论文 · doi:10.1016/j.jcrs.2017.08.013 · 被引 20 次

白内障与眼前节手术

图文摘要. 回顾性比较病例系列 · 180 只眼. 随访时间: 18 months. 术前瞳孔较小会降低旋转非对称多焦点人工晶状体的视觉质量。
图文摘要: SVG · PNG · JSON · 可在注明出处的前提下自由使用(CC BY 4.0)

要点速览

术前瞳孔较小会降低旋转非对称多焦点人工晶状体的视觉质量。

研究设计
回顾性比较病例系列
样本
180 只眼
随访时间
18 months

摘要

本文摘要以原文(英文)显示,因为该文章未采用允许翻译的开放许可协议。

PURPOSE: To evaluate the influences of preoperative pupil parameters on the visual outcomes of the SBL-3, a rotationally asymmetric multifocal intraocular lens (IOL) with a surface-embedded near segment. SETTING: Cathedral Eye Clinic, Belfast, Northern Ireland, United Kingdom. DESIGN: Retrospective comparative case series. METHODS: Postoperatively, patients divided into 4 groups according to their pupil size as follows: Group A: 2.50 to 2.99 mm, Group B: 3.00 to 3.50 mm, Group C: 3.51 to 4.00 mm, and Group D: 4.01 to 4.50 mm. The uncorrected distance (UDVA), intermediate (UIVA), and near (UNVA) visual acuities, IOL centration and tilt, and quality of vision (QoV) questionnaires were compared between the 4 groups for 18 months postoperatively. RESULTS: The study comprised 90 patients (180 eyes). The mean preoperative pupil (photopic and mesopic) diameter was 4.3 mm ± 0.3 (SD) and 5.6 ± 1.4 mm, respectively, which decreased to 3.8 ± 0.7 mm and 4.9 ± 1.2 mm, respectively, at 18 months. Eighteen months postoperatively, both photopic and mesopic pupil groups had a statistically significant reduction in size from preoperative levels. No significant differences in UDVA, UIVA, and UNVA were found between the groups (P > .001). Significant differences in the QoV questionnaire day scores and night scores were found between the 4 groups (P < .001). CONCLUSIONS: The rotationally asymmetric multifocal IOL provided excellent optical performance during 18-months follow-up. The preoperative photopic pupil is an important parameter for consideration of this type of IOL because smaller pupils have a significant negative subjective impact on QoV.

关键词: pupil size; visual quality; visual acuity; cataract surgery outcomes

获取全文

引用格式

Pazo, E. E., McNeely, R. N., Richoz, O., Nesbit, A. M., Moore, T., Moore, J. E. (2017). Pupil influence on the quality of vision in rotationally asymmetric multifocal IOLs with surface-embedded near segment. Journal of Cataract & Refractive Surgery. https://doi.org/10.1016/j.jcrs.2017.08.013

显示 BibTeX
@article{pazo2017pupil,
  title = {{Pupil influence on the quality of vision in rotationally asymmetric multifocal IOLs with surface-embedded near segment}},
  author = {Pazo, Emmanuel Eric and McNeely, Richard N. and Richoz, Olivier and Nesbit, Andrew M. and Moore, Tara and Moore, Jonathan Edward},
  journal = {Journal of Cataract & Refractive Surgery},
  year = {2017},
  doi = {10.1016/j.jcrs.2017.08.013},
  url = {https://doi.org/10.1016/j.jcrs.2017.08.013},
}

相关研究