Exploración de modelos de aprendizaje automático para la seguridad del vault en el implante de ICL: un análisis comparativo de modelos de regresión y de clasificación
Título original: Exploring Machine Learning Models for Vault Safety in ICL Implantation: A Comparative Analysis of Regression and Classification Models
Qing Zhang, Qi Li, Zhilong Yu, Ruibo Yang, Emmanuel Eric Pazo, Yue Huang, Hui Liu, Chen Zhang, Salissou Moutari, Shaozhen Zhao
Cataratas y cirugía del segmento anteriorIA y aprendizaje profundo
De un vistazo
Clasificar el vault en categorías clínicas funciona mejor que predecir su altura exacta tras la cirugía ICL.
- Diseño
- Estudio retrospectivo de aprendizaje automático
- Muestra
- Pacientes con ICL V4c
- AUC, vault < 250 µm
- 0.89
- AUC, vault > 750 µm
- 0.88
- MAE de regresión (random forest)
- 134.0 µm
Resumen
INTRODUCCIÓN: La predicción precisa de la altura del vault posoperatorio tras el implante de la lente de colámero implantable (ICL) V4c es fundamental para minimizar las complicaciones y lograr resultados quirúrgicos óptimos. Este estudio pretende evaluar el rendimiento de modelos de aprendizaje automático para predecir la altura del vault posoperatorio, con enfoques tanto de regresión como de clasificación. MÉTODOS: Este estudio retrospectivo analizó datos biométricos y demográficos, como la profundidad de la cámara anterior, la distancia blanco-blanco y el tamaño de la ICL, entre otras variables. Se desarrollaron modelos de regresión y de clasificación con los algoritmos gradient boosting, random forest y CatBoost. Los modelos de regresión predijeron la altura del vault como variable continua, mientras que los de clasificación la categorizaron en tareas binarias y multiclase. El rendimiento se evaluó con métricas como el error absoluto medio (MAE) y la raíz del error cuadrático medio (RMSE) para los modelos de regresión, y con la exactitud, la puntuación F1 y el área bajo la curva (AUC) para los modelos de clasificación. RESULTADOS: Los modelos de regresión mostraron un rendimiento predictivo moderado; random forest obtuvo el mejor resultado (MAE: 134.0 µm, RMSE: 171.3 µm, coeficiente de correlación de Pearson: 0.45). Por otra parte, los modelos de clasificación mostraron mayor aplicabilidad clínica que los enfoques de regresión. En la tarea de clasificación binaria (vault < 250 µm frente a ≥ 250 µm), gradient boosting logró el mejor rendimiento global, con una exactitud del 89 ± 12% y un AUC de 0.89. En la tarea de predecir vault > 750 µm frente a ≤ 750 µm, random forest fue el clasificador más eficaz, con una exactitud del 86 ± 9% y un AUC de 0.88. En la clasificación multiclase, los modelos mostraron un rendimiento superior al predecir alturas de vault intermedias (250 µm ≤ vault ≤ 750 µm); random forest alcanzó la mayor exactitud, del 94.6%, en esta categoría. Sin embargo, todos los modelos tuvieron dificultades para clasificar con precisión las categorías extremas de vault. CONCLUSIONES: Los modelos de clasificación, en particular gradient boosting y random forest, mostraron un gran potencial para predecir categorías de vault clínicamente relevantes, lo que permite una planificación quirúrgica personalizada y una mejor gestión del riesgo. Aunque los modelos de regresión ofrecieron información moderada, sus limitaciones indican que los enfoques de clasificación son más adecuados para las aplicaciones clínicas. La investigación futura debería centrarse en mejorar la precisión de los modelos para predecir vaults extremos e integrar técnicas avanzadas, como el aprendizaje profundo por conjuntos, para afinar aún más los resultados.
Traducido del resumen original en inglés (licencia: CC BY-NC).
Mostrar el resumen original
INTRODUCTION: Accurate prediction of postoperative vault height following implantable collamer lens (ICL) V4c implantation is critical for minimizing complications and achieving optimal surgical outcomes. This study aims to evaluate the performance of machine learning models in predicting postoperative vault height, focusing on both regression and classification approaches. METHODS: This retrospective study analyzed biometric and demographic data, including anterior chamber depth, white-to-white distance, and ICL size, among other variables. Regression and classification models were developed using gradient boosting, random forest, and CatBoost algorithms. Regression models predicted vault height as a continuous variable, while classification models categorized vault heights into binary and multi-class tasks. Model performance was evaluated using metrics including the mean absolute error (MAE) and root mean squared error (RMSE) for regression models, while accuracy, F1-score, and area under the curve (AUC) were used for classification models. RESULTS: Regression models demonstrated moderate predictive performance, with random forest delivering the best performance (MAE: 134.0 µm, RMSE: 171.3 µm, Pearson's correlation coefficient: 0.45). On the other hand, classification models exhibited greater clinical applicability than regression approaches. For the binary classification task (vault < 250 µm vs. ≥ 250 µm), gradient boosting achieved the highest overall performance, with accuracy of 89 ± 12% and an AUC of 0.89. In the task of predicting vault > 750 µm vs. ≤ 750 µm, random forest emerged as the most effective classifier, achieving accuracy of 86 ± 9% and an AUC of 0.88. In multi-class classification, models demonstrated superior performance in predicting intermediate vault heights (250 µm ≤ vault ≤ 750 µm). Random forest achieved the highest accuracy of 94.6% in this category. However, all models faced challenges in accurately classifying extreme vault categories. CONCLUSIONS: Classification models, particularly gradient boosting and random forest, demonstrated strong potential for predicting clinically significant vault categories, enabling personalized surgical planning and improved risk management. While regression models offered moderate insights, their limitations suggest that classification approaches are better suited for clinical applications. Future research should focus on enhancing model accuracy for extreme vault prediction and integrating advanced techniques, such as ensemble deep learning, to further refine outcomes.
Palabras clave: implantable collamer lens; ICL V4c; classification models; regression models; gradient boosting; random forest; CatBoost; anterior chamber depth
Acceso
Cómo citar
Mostrar BibTeX
@article{zhang2025exploring,
title = {{Exploring Machine Learning Models for Vault Safety in ICL Implantation: A Comparative Analysis of Regression and Classification Models}},
author = {Zhang, Qing and Li, Qi and Yu, Zhilong and Yang, Ruibo and Pazo, Emmanuel Eric and Huang, Yue and Liu, Hui and Zhang, Chen and Moutari, Salissou and Zhao, Shaozhen},
journal = {Ophthalmology and Therapy},
year = {2025},
doi = {10.1007/s40123-025-01173-4},
url = {https://doi.org/10.1007/s40123-025-01173-4},
}
Trabajos relacionados
- Predicción de la refracción ciclopléjica basada en aprendizaje automático con el Eyerobo Vision Screener: diseño, un estudio transversal comparativo de dispositivos (2026)
- Comparación múltiple de 8 fórmulas biométricas de lente intraocular, incluida una fórmula de lente delgada basada en aprendizaje automático (MM) y una fórmula de trazado de rayos integrada en la tomografía de coherencia óptica del segmento anterior (2024)
- Asociación de los conocimientos y actitudes sobre el tratamiento anti-VEGF con la interrupción autodeclarada del tratamiento: un estudio de clasificación con separación temporal (2026)
- Medición automatizada basada en aprendizaje profundo del volumen de retinosquisis y desprendimiento en la miopía patológica con contracción escleral posterior (2026)
- Medición y evaluación automáticas de las estructuras anatómicas del segmento anterior en imágenes de BMU mediante un enfoque basado en aprendizaje profundo (2026)