表面埋込型近用部をもつ回転非対称多焦点 IOL における瞳孔が視覚の質に及ぼす影響

原題: Pupil influence on the quality of vision in rotationally asymmetric multifocal IOLs with surface-embedded near segment

Emmanuel Eric Pazo, Richard N. McNeely, Olivier Richoz, Andrew M. Nesbit, Tara Moore, Jonathan Edward Moore

Journal of Cataract & Refractive Surgery, 2017 · 原著論文 · doi:10.1016/j.jcrs.2017.08.013 · 被引用 20 回

白内障・前眼部手術

ビジュアルアブストラクト. 後ろ向き比較症例集積 · 180 眼. 経過観察期間: 18 months. 術前の瞳孔が小さいと、回転非対称多焦点 IOL の視覚の質が低下する。
ビジュアルアブストラクト: SVG · PNG · JSON · 出典を明記すれば自由に再利用可(CC BY 4.0)

要点

術前の瞳孔が小さいと、回転非対称多焦点 IOL の視覚の質が低下する。

研究デザイン
後ろ向き比較症例集積
対象
180 眼
経過観察期間
18 months

抄録

この抄録は原語(英語)で表示しています。論文が翻訳を認めるオープンライセンスで公開されていないためです。

PURPOSE: To evaluate the influences of preoperative pupil parameters on the visual outcomes of the SBL-3, a rotationally asymmetric multifocal intraocular lens (IOL) with a surface-embedded near segment. SETTING: Cathedral Eye Clinic, Belfast, Northern Ireland, United Kingdom. DESIGN: Retrospective comparative case series. METHODS: Postoperatively, patients divided into 4 groups according to their pupil size as follows: Group A: 2.50 to 2.99 mm, Group B: 3.00 to 3.50 mm, Group C: 3.51 to 4.00 mm, and Group D: 4.01 to 4.50 mm. The uncorrected distance (UDVA), intermediate (UIVA), and near (UNVA) visual acuities, IOL centration and tilt, and quality of vision (QoV) questionnaires were compared between the 4 groups for 18 months postoperatively. RESULTS: The study comprised 90 patients (180 eyes). The mean preoperative pupil (photopic and mesopic) diameter was 4.3 mm ± 0.3 (SD) and 5.6 ± 1.4 mm, respectively, which decreased to 3.8 ± 0.7 mm and 4.9 ± 1.2 mm, respectively, at 18 months. Eighteen months postoperatively, both photopic and mesopic pupil groups had a statistically significant reduction in size from preoperative levels. No significant differences in UDVA, UIVA, and UNVA were found between the groups (P > .001). Significant differences in the QoV questionnaire day scores and night scores were found between the 4 groups (P < .001). CONCLUSIONS: The rotationally asymmetric multifocal IOL provided excellent optical performance during 18-months follow-up. The preoperative photopic pupil is an important parameter for consideration of this type of IOL because smaller pupils have a significant negative subjective impact on QoV.

キーワード: pupil size; visual quality; visual acuity; cataract surgery outcomes

アクセス

引用方法

Pazo, E. E., McNeely, R. N., Richoz, O., Nesbit, A. M., Moore, T., Moore, J. E. (2017). Pupil influence on the quality of vision in rotationally asymmetric multifocal IOLs with surface-embedded near segment. Journal of Cataract & Refractive Surgery. https://doi.org/10.1016/j.jcrs.2017.08.013

BibTeX を表示
@article{pazo2017pupil,
  title = {{Pupil influence on the quality of vision in rotationally asymmetric multifocal IOLs with surface-embedded near segment}},
  author = {Pazo, Emmanuel Eric and McNeely, Richard N. and Richoz, Olivier and Nesbit, Andrew M. and Moore, Tara and Moore, Jonathan Edward},
  journal = {Journal of Cataract & Refractive Surgery},
  year = {2017},
  doi = {10.1016/j.jcrs.2017.08.013},
  url = {https://doi.org/10.1016/j.jcrs.2017.08.013},
}

関連する論文