表面埋込型近用部をもつ回転非対称多焦点 IOL における瞳孔が視覚の質に及ぼす影響
原題: Pupil influence on the quality of vision in rotationally asymmetric multifocal IOLs with surface-embedded near segment
Emmanuel Eric Pazo, Richard N. McNeely, Olivier Richoz, Andrew M. Nesbit, Tara Moore, Jonathan Edward Moore
要点
術前の瞳孔が小さいと、回転非対称多焦点 IOL の視覚の質が低下する。
- 研究デザイン
- 後ろ向き比較症例集積
- 対象
- 180 眼
- 経過観察期間
- 18 months
抄録
この抄録は原語(英語)で表示しています。論文が翻訳を認めるオープンライセンスで公開されていないためです。
PURPOSE: To evaluate the influences of preoperative pupil parameters on the visual outcomes of the SBL-3, a rotationally asymmetric multifocal intraocular lens (IOL) with a surface-embedded near segment. SETTING: Cathedral Eye Clinic, Belfast, Northern Ireland, United Kingdom. DESIGN: Retrospective comparative case series. METHODS: Postoperatively, patients divided into 4 groups according to their pupil size as follows: Group A: 2.50 to 2.99 mm, Group B: 3.00 to 3.50 mm, Group C: 3.51 to 4.00 mm, and Group D: 4.01 to 4.50 mm. The uncorrected distance (UDVA), intermediate (UIVA), and near (UNVA) visual acuities, IOL centration and tilt, and quality of vision (QoV) questionnaires were compared between the 4 groups for 18 months postoperatively. RESULTS: The study comprised 90 patients (180 eyes). The mean preoperative pupil (photopic and mesopic) diameter was 4.3 mm ± 0.3 (SD) and 5.6 ± 1.4 mm, respectively, which decreased to 3.8 ± 0.7 mm and 4.9 ± 1.2 mm, respectively, at 18 months. Eighteen months postoperatively, both photopic and mesopic pupil groups had a statistically significant reduction in size from preoperative levels. No significant differences in UDVA, UIVA, and UNVA were found between the groups (P > .001). Significant differences in the QoV questionnaire day scores and night scores were found between the 4 groups (P < .001). CONCLUSIONS: The rotationally asymmetric multifocal IOL provided excellent optical performance during 18-months follow-up. The preoperative photopic pupil is an important parameter for consideration of this type of IOL because smaller pupils have a significant negative subjective impact on QoV.
キーワード: pupil size; visual quality; visual acuity; cataract surgery outcomes
アクセス
引用方法
BibTeX を表示
@article{pazo2017pupil,
title = {{Pupil influence on the quality of vision in rotationally asymmetric multifocal IOLs with surface-embedded near segment}},
author = {Pazo, Emmanuel Eric and McNeely, Richard N. and Richoz, Olivier and Nesbit, Andrew M. and Moore, Tara and Moore, Jonathan Edward},
journal = {Journal of Cataract & Refractive Surgery},
year = {2017},
doi = {10.1016/j.jcrs.2017.08.013},
url = {https://doi.org/10.1016/j.jcrs.2017.08.013},
}