2 種類の屈折型回転非対称多焦点眼内レンズの視覚の質と視機能の比較
原題: Visual quality and performance comparison between 2 refractive rotationally asymmetric multifocal intraocular lenses
Richard N. McNeely, Emmanuel Eric Pazo, Andrew Spence, Olivier Richoz, Andrew M. Nesbit, Tara Moore, Jonathan Edward Moore
要点
2 種類の非対称多焦点 IOL はいずれも優れた視覚の質をもたらし、SBL-3 のほうが近見視力が良好であった。
- 研究デザイン
- 後ろ向き症例集積
- 対象
- 180 眼
- 経過観察期間
- 12 months
抄録
この抄録は原語(英語)で表示しています。論文が翻訳を認めるオープンライセンスで公開されていないためです。
PURPOSE: To compare the 12-month postoperative quality of vision and visual performance of 2 different refractive rotationally asymmetric multifocal intraocular lenses (IOLs). SETTING: Cathedral Eye Clinic, Belfast, Northern Ireland, United Kingdom. DESIGN: Retrospective case series. METHODS: Refractive lens exchange (RLE) patients were divided into 2 groups. Group A comprised eyes receiving a Lentis Mplus LS-312 MF30 IOL and Group B, eyes receiving a Lenstec SBL-3 IOL. Refraction, uncorrected (UDVA) and corrected distance visual acuities, uncorrected intermediate (UIVA) and near (UNVA) visual acuities, distance-corrected intermediate and near (DCNVA) visual acuities, and quality of vision were evaluated preoperatively and up to 12 months postoperatively. RESULTS: Each group comprised 90 eyes. Both groups had a high level of quality of vision 12 months postoperatively with no significant difference between the 2 groups (P = .919). There was no significant between-group difference in mean monocular and binocular UDVA, monocular UIVA, or monocular UNVA. Group B had statistically significantly better mean monocular DCNVA (P = .049), binocular UNVA (P = .011), and binocular DCNVA (P = .035). Group B had a higher percentage of complete spectacle independence. CONCLUSIONS: Both refractive rotationally asymmetric multifocal IOLs provided an excellent level of quality of vision 12 months postoperatively. Both IOL models restored distance, intermediate, and near visual function; however the IOLs in Group B provided better near visual performance.
キーワード: refractive lens exchange; visual quality; visual acuity; intermediate visual acuity; spectacle independence; intraocular lens comparison
アクセス
引用方法
BibTeX を表示
@article{mcneely2017visual,
title = {{Visual quality and performance comparison between 2 refractive rotationally asymmetric multifocal intraocular lenses}},
author = {McNeely, Richard N. and Pazo, Emmanuel Eric and Spence, Andrew and Richoz, Olivier and Nesbit, Andrew M. and Moore, Tara and Moore, Jonathan Edward},
journal = {Journal of Cataract & Refractive Surgery},
year = {2017},
doi = {10.1016/j.jcrs.2017.05.039},
url = {https://doi.org/10.1016/j.jcrs.2017.05.039},
}