2 种折射型旋转非对称多焦点人工晶状体的视觉质量与视功能比较

原文标题: Visual quality and performance comparison between 2 refractive rotationally asymmetric multifocal intraocular lenses

Richard N. McNeely, Emmanuel Eric Pazo, Andrew Spence, Olivier Richoz, Andrew M. Nesbit, Tara Moore, Jonathan Edward Moore

Journal of Cataract & Refractive Surgery, 2017 · 期刊论文 · doi:10.1016/j.jcrs.2017.05.039 · 被引 46 次

白内障与眼前节手术

图文摘要. 回顾性病例系列 · 180 只眼. 随访时间: 12 months. 两种非对称多焦点人工晶状体均提供了出色的视觉质量;SBL-3 的近视力更好。
图文摘要: SVG · PNG · JSON · 可在注明出处的前提下自由使用(CC BY 4.0)

要点速览

两种非对称多焦点人工晶状体均提供了出色的视觉质量;SBL-3 的近视力更好。

研究设计
回顾性病例系列
样本
180 只眼
随访时间
12 months

摘要

本文摘要以原文(英文)显示,因为该文章未采用允许翻译的开放许可协议。

PURPOSE: To compare the 12-month postoperative quality of vision and visual performance of 2 different refractive rotationally asymmetric multifocal intraocular lenses (IOLs). SETTING: Cathedral Eye Clinic, Belfast, Northern Ireland, United Kingdom. DESIGN: Retrospective case series. METHODS: Refractive lens exchange (RLE) patients were divided into 2 groups. Group A comprised eyes receiving a Lentis Mplus LS-312 MF30 IOL and Group B, eyes receiving a Lenstec SBL-3 IOL. Refraction, uncorrected (UDVA) and corrected distance visual acuities, uncorrected intermediate (UIVA) and near (UNVA) visual acuities, distance-corrected intermediate and near (DCNVA) visual acuities, and quality of vision were evaluated preoperatively and up to 12 months postoperatively. RESULTS: Each group comprised 90 eyes. Both groups had a high level of quality of vision 12 months postoperatively with no significant difference between the 2 groups (P = .919). There was no significant between-group difference in mean monocular and binocular UDVA, monocular UIVA, or monocular UNVA. Group B had statistically significantly better mean monocular DCNVA (P = .049), binocular UNVA (P = .011), and binocular DCNVA (P = .035). Group B had a higher percentage of complete spectacle independence. CONCLUSIONS: Both refractive rotationally asymmetric multifocal IOLs provided an excellent level of quality of vision 12 months postoperatively. Both IOL models restored distance, intermediate, and near visual function; however the IOLs in Group B provided better near visual performance.

关键词: refractive lens exchange; visual quality; visual acuity; intermediate visual acuity; spectacle independence; intraocular lens comparison

获取全文

引用格式

McNeely, R. N., Pazo, E. E., Spence, A., Richoz, O., Nesbit, A. M., Moore, T., Moore, J. E. (2017). Visual quality and performance comparison between 2 refractive rotationally asymmetric multifocal intraocular lenses. Journal of Cataract & Refractive Surgery. https://doi.org/10.1016/j.jcrs.2017.05.039

显示 BibTeX
@article{mcneely2017visual,
  title = {{Visual quality and performance comparison between 2 refractive rotationally asymmetric multifocal intraocular lenses}},
  author = {McNeely, Richard N. and Pazo, Emmanuel Eric and Spence, Andrew and Richoz, Olivier and Nesbit, Andrew M. and Moore, Tara and Moore, Jonathan Edward},
  journal = {Journal of Cataract & Refractive Surgery},
  year = {2017},
  doi = {10.1016/j.jcrs.2017.05.039},
  url = {https://doi.org/10.1016/j.jcrs.2017.05.039},
}

相关研究