Impacto del tamaño pupilar en la calidad visual de pacientes con lente de colámero implantable (ICL V4c): un estudio piloto

Título original: Impact of pupil size upon the quality of vision in patients implanted with an implantable collamer lens (ICL V4c): A pilot study

Qing Zhang, He Huang, Yi Wu, Guanghao Qin, Liangzhe Li, Jiayan Chen, Huixin Che, Tao Yao, Chunhong Yan, Ling Xu, Jonathan Edward Moore, Wei He, Sile Yu, Emmanuel Eric Pazo, Xingru He

Research Square, 2022 · preprint · doi:10.21203/rs.3.rs-2309603/v1 · Acceso abierto (CC BY)

Cataratas y cirugía del segmento anterior

Resumen visual. Estudio retrospectivo · Ojos con ICL V4c. Rs, pupila mesópica frente a halos: 0.624; Puntuación QoV nocturna media: 8.58. Las pupilas más grandes tras el implante de ICL se asocian a una peor calidad visual subjetiva.
Resumen visual: SVG · PNG · JSON · reutilización libre citando la fuente (CC BY 4.0)

De un vistazo

Las pupilas más grandes tras el implante de ICL se asocian a una peor calidad visual subjetiva.

Diseño
Estudio retrospectivo
Muestra
Ojos con ICL V4c
Rs, pupila mesópica frente a halos
0.624
Puntuación QoV nocturna media
8.58

Resumen

Resumen Objetivo: Este estudio tuvo como objetivo evaluar la influencia del tamaño pupilar en la calidad visual subjetiva en sujetos con lentes de colámero implantables (ICL). Métodos: Este estudio retrospectivo evaluó ojos con implante de ICL (V4c) y los clasificó en grupos crecientes según el tamaño pupilar. Se evaluaron y compararon el tamaño pupilar fotópico y mesópico preoperatorio y posoperatorio, la agudeza visual de lejos sin corrección (UDVA) y la puntuación del cuestionario de calidad visual (QoV). Resultados: A los 3 meses del posoperatorio, la puntuación QoV media diurna y nocturna fue de 9.34 ± 0.76 y 8.58 ± 1.29, respectivamente. El tamaño pupilar mesópico medio (MPS) y el tamaño pupilar fotópico medio (PPS) fueron de 6.59 ± 0.79 mm y 4.61 ± 0.74 mm, respectivamente. El PPS se correlacionó negativamente con la «QoV diurna» (Rs = -0.413, P=0.001) y positivamente con los «halos» (Rs = 0.568*, P<0.001) y la "visión borrosa" (Rs = 0.243, P = 0.04). El MPS se correlacionó negativamente con la «QoV nocturna» (Rs = -0.426, P=0.001) y positivamente con los "halos" (Rs = 0.624*, P < 0.001), los "destellos en estrella" (Rs = 0.233, P=0.046) y la "dificultad para enfocar" (Rs = 0.27, P = 0.025). Conclusión: Los resultados de este estudio sugieren que el aumento del tamaño pupilar tiene una correlación negativa con la calidad visual subjetiva (QoV) en las puntuaciones diurnas y nocturnas. Un tamaño pupilar menor se asoció a mejores puntuaciones QoV nocturnas, lo que indica que se necesita más investigación.

Traducido del resumen original en inglés (licencia: CC BY).

Mostrar el resumen original

Abstract Objective: This study aimed to assess the influence of pupil size on subjective visual quality in subjects with implanted collamer lenses (ICLs). Methods: This retrospective study assessed eyes implanted with ICL (V4c) and categorized them into incremental groups according to pupil size. Preoperative and postoperative photopic and mesopic pupil size, uncorrected distance visual acuity (UDVA), and quality of vision (QoV) questionnaire score were assessed and compared. Results: Post-operatively at 3-months the mean QoV score for day and night was 9.34 ± 0.76 and 8.58 ± 1.29 respectively. The mean mesopic pupil size (MPS) and mean photopic pupil size (PPS) was 6.59 ± 0.79 mm and 4.61 ± 0.74 mm respectively. PPS negatively correlated with “QoV day” (Rs = -0.413, P=0.001), positively correlated with “haloes” (Rs = 0.568*, P<0.001) and "blurred vision" (Rs = 0.243, P = 0.04) respectively. MPS negatively correlated with “QoV night” (Rs = -0.426, P=0.001), positively correlated with "haloes" (Rs = 0.624*, P < 0.001), "starburst" (Rs = 0.233, P=0.046) and "difficulty focusing" (Rs = 0.27, P = 0.025) respectively. Conclusion: The findings of this study suggest that increasing pupil size has a negative correlation on the subjective visual quality (QoV) for day and night scores. Smaller pupil size had better QoV night scores suggesting further investigation is needed.

Palabras clave: implantable collamer lens; pupil size; subjective visual quality; HALOE; starburst; uncorrected distance visual acuity; refractive surgery outcomes

Acceso

Cómo citar

Zhang, Q., Huang, H., Wu, Y., Qin, G., Li, L., Chen, J., Che, H., Yao, T., Yan, C., Xu, L., Moore, J. E., He, W., Yu, S., Pazo, E. E., He, X. (2022). Impact of pupil size upon the quality of vision in patients implanted with an implantable collamer lens (ICL V4c): A pilot study. Research Square. https://doi.org/10.21203/rs.3.rs-2309603/v1

Mostrar BibTeX
@article{zhang2022impact,
  title = {{Impact of pupil size upon the quality of vision in patients implanted with an implantable collamer lens (ICL V4c): A pilot study}},
  author = {Zhang, Qing and Huang, He and Wu, Yi and Qin, Guanghao and Li, Liangzhe and Chen, Jiayan and Che, Huixin and Yao, Tao and Yan, Chunhong and Xu, Ling and Moore, Jonathan Edward and He, Wei and Yu, Sile and Pazo, Emmanuel Eric and He, Xingru},
  journal = {Research Square},
  year = {2022},
  doi = {10.21203/rs.3.rs-2309603/v1},
  url = {https://doi.org/10.21203/rs.3.rs-2309603/v1},
}

Trabajos relacionados