瞳孔大小对植入式胶原镜(ICL V4c)患者视觉质量的影响:一项初步研究
原文标题: Impact of pupil size upon the quality of vision in patients implanted with an implantable collamer lens (ICL V4c): A pilot study
Qing Zhang, He Huang, Yi Wu, Guanghao Qin, Liangzhe Li, Jiayan Chen, Huixin Che, Tao Yao, Chunhong Yan, Ling Xu, Jonathan Edward Moore, Wei He, Sile Yu, Emmanuel Eric Pazo, Xingru He
要点速览
ICL 植入术后瞳孔越大,主观视觉质量越差。
- 研究设计
- 回顾性研究
- 样本
- ICL V4c 眼
- Rs(中间视觉瞳孔与光晕)
- 0.624
- 夜间 QoV 平均评分
- 8.58
摘要
摘要 目的:本研究旨在评估瞳孔大小对植入式胶原镜(ICL)受试者主观视觉质量的影响。方法:这项回顾性研究评估了植入 ICL(V4c)的眼,并按瞳孔大小分为递增的若干组。评估并比较术前和术后的明视及中间视觉瞳孔大小、裸眼远视力(UDVA)和视觉质量(QoV)问卷评分。结果:术后 3 个月时,日间和夜间 QoV 平均评分分别为 9.34 ± 0.76 和 8.58 ± 1.29。平均中间视觉瞳孔大小(MPS)和平均明视瞳孔大小(PPS)分别为 6.59 ± 0.79 mm 和 4.61 ± 0.74 mm。PPS 与“日间 QoV”呈负相关(Rs = -0.413,P=0.001),与“光晕”(Rs = 0.568*,P<0.001)和“视物模糊”(Rs = 0.243,P = 0.04)呈正相关。MPS 与“夜间 QoV”呈负相关(Rs = -0.426,P=0.001),与“光晕”(Rs = 0.624*,P < 0.001)、“星芒”(Rs = 0.233,P=0.046)和“对焦困难”(Rs = 0.27,P = 0.025)呈正相关。结论:本研究结果提示,瞳孔增大与日间和夜间主观视觉质量(QoV)评分呈负相关。瞳孔较小者夜间 QoV 评分较好,提示有必要进一步研究。
译自英文原文摘要(许可协议:CC BY)。
显示英文原文摘要
Abstract Objective: This study aimed to assess the influence of pupil size on subjective visual quality in subjects with implanted collamer lenses (ICLs). Methods: This retrospective study assessed eyes implanted with ICL (V4c) and categorized them into incremental groups according to pupil size. Preoperative and postoperative photopic and mesopic pupil size, uncorrected distance visual acuity (UDVA), and quality of vision (QoV) questionnaire score were assessed and compared. Results: Post-operatively at 3-months the mean QoV score for day and night was 9.34 ± 0.76 and 8.58 ± 1.29 respectively. The mean mesopic pupil size (MPS) and mean photopic pupil size (PPS) was 6.59 ± 0.79 mm and 4.61 ± 0.74 mm respectively. PPS negatively correlated with “QoV day” (Rs = -0.413, P=0.001), positively correlated with “haloes” (Rs = 0.568*, P<0.001) and "blurred vision" (Rs = 0.243, P = 0.04) respectively. MPS negatively correlated with “QoV night” (Rs = -0.426, P=0.001), positively correlated with "haloes" (Rs = 0.624*, P < 0.001), "starburst" (Rs = 0.233, P=0.046) and "difficulty focusing" (Rs = 0.27, P = 0.025) respectively. Conclusion: The findings of this study suggest that increasing pupil size has a negative correlation on the subjective visual quality (QoV) for day and night scores. Smaller pupil size had better QoV night scores suggesting further investigation is needed.
关键词: implantable collamer lens; pupil size; subjective visual quality; HALOE; starburst; uncorrected distance visual acuity; refractive surgery outcomes
获取全文
引用格式
显示 BibTeX
@article{zhang2022impact,
title = {{Impact of pupil size upon the quality of vision in patients implanted with an implantable collamer lens (ICL V4c): A pilot study}},
author = {Zhang, Qing and Huang, He and Wu, Yi and Qin, Guanghao and Li, Liangzhe and Chen, Jiayan and Che, Huixin and Yao, Tao and Yan, Chunhong and Xu, Ling and Moore, Jonathan Edward and He, Wei and Yu, Sile and Pazo, Emmanuel Eric and He, Xingru},
journal = {Research Square},
year = {2022},
doi = {10.21203/rs.3.rs-2309603/v1},
url = {https://doi.org/10.21203/rs.3.rs-2309603/v1},
}