Impact de la taille pupillaire sur la qualité de vision des patients implantés d'une lentille en collamer implantable (ICL V4c) : une étude pilote
Titre original : Impact of pupil size upon the quality of vision in patients implanted with an implantable collamer lens (ICL V4c): A pilot study
Qing Zhang, He Huang, Yi Wu, Guanghao Qin, Liangzhe Li, Jiayan Chen, Huixin Che, Tao Yao, Chunhong Yan, Ling Xu, Jonathan Edward Moore, Wei He, Sile Yu, Emmanuel Eric Pazo, Xingru He
Cataracte et chirurgie du segment antérieur
En bref
Des pupilles plus larges après implantation d'ICL sont associées à une moins bonne qualité de vision subjective.
- Type d'étude
- Étude rétrospective
- Échantillon
- Yeux implantés d'une ICL V4c
- Rs, pupille mésopique contre halos
- 0.624
- Score QoV nocturne moyen
- 8.58
Résumé
Résumé Objectif : Cette étude visait à évaluer l'influence de la taille pupillaire sur la qualité visuelle subjective chez des sujets porteurs de lentilles en collamer implantables (ICL). Méthodes : Cette étude rétrospective a évalué des yeux implantés d'une ICL (V4c) et les a répartis en groupes croissants selon la taille pupillaire. Les tailles pupillaires photopique et mésopique pré- et postopératoires, l'acuité visuelle de loin non corrigée (UDVA) et le score du questionnaire de qualité de vision (QoV) ont été évalués et comparés. Résultats : À 3 mois postopératoires, les scores QoV moyens de jour et de nuit étaient respectivement de 9.34 ± 0.76 et 8.58 ± 1.29. La taille pupillaire mésopique moyenne (MPS) et la taille pupillaire photopique moyenne (PPS) étaient respectivement de 6.59 ± 0.79 mm et 4.61 ± 0.74 mm. La PPS était négativement corrélée à la « QoV de jour » (Rs = -0.413, P=0.001) et positivement corrélée aux « halos » (Rs = 0.568*, P<0.001) et à la "vision floue" (Rs = 0.243, P = 0.04). La MPS était négativement corrélée à la « QoV de nuit » (Rs = -0.426, P=0.001) et positivement corrélée aux "halos" (Rs = 0.624*, P < 0.001), aux "éclats en étoile" (Rs = 0.233, P=0.046) et à la "difficulté de mise au point" (Rs = 0.27, P = 0.025). Conclusion : Les résultats de cette étude suggèrent qu'une taille pupillaire croissante est négativement corrélée à la qualité de vision subjective (QoV) de jour et de nuit. Les petites pupilles s'accompagnaient de meilleurs scores QoV de nuit, ce qui justifie des recherches complémentaires.
Traduit du résumé original en anglais (licence : CC BY).
Afficher le résumé original
Abstract Objective: This study aimed to assess the influence of pupil size on subjective visual quality in subjects with implanted collamer lenses (ICLs). Methods: This retrospective study assessed eyes implanted with ICL (V4c) and categorized them into incremental groups according to pupil size. Preoperative and postoperative photopic and mesopic pupil size, uncorrected distance visual acuity (UDVA), and quality of vision (QoV) questionnaire score were assessed and compared. Results: Post-operatively at 3-months the mean QoV score for day and night was 9.34 ± 0.76 and 8.58 ± 1.29 respectively. The mean mesopic pupil size (MPS) and mean photopic pupil size (PPS) was 6.59 ± 0.79 mm and 4.61 ± 0.74 mm respectively. PPS negatively correlated with “QoV day” (Rs = -0.413, P=0.001), positively correlated with “haloes” (Rs = 0.568*, P<0.001) and "blurred vision" (Rs = 0.243, P = 0.04) respectively. MPS negatively correlated with “QoV night” (Rs = -0.426, P=0.001), positively correlated with "haloes" (Rs = 0.624*, P < 0.001), "starburst" (Rs = 0.233, P=0.046) and "difficulty focusing" (Rs = 0.27, P = 0.025) respectively. Conclusion: The findings of this study suggest that increasing pupil size has a negative correlation on the subjective visual quality (QoV) for day and night scores. Smaller pupil size had better QoV night scores suggesting further investigation is needed.
Mots-clés : implantable collamer lens; pupil size; subjective visual quality; HALOE; starburst; uncorrected distance visual acuity; refractive surgery outcomes
Accès
Comment citer
Afficher le BibTeX
@article{zhang2022impact,
title = {{Impact of pupil size upon the quality of vision in patients implanted with an implantable collamer lens (ICL V4c): A pilot study}},
author = {Zhang, Qing and Huang, He and Wu, Yi and Qin, Guanghao and Li, Liangzhe and Chen, Jiayan and Che, Huixin and Yao, Tao and Yan, Chunhong and Xu, Ling and Moore, Jonathan Edward and He, Wei and Yu, Sile and Pazo, Emmanuel Eric and He, Xingru},
journal = {Research Square},
year = {2022},
doi = {10.21203/rs.3.rs-2309603/v1},
url = {https://doi.org/10.21203/rs.3.rs-2309603/v1},
}
Travaux liés
- Observance du suivi à long terme après implantation d'une lentille en collamer implantable chez des patients fortement myopes : une étude monocentrique de cohorte rétrospective et d'enquête CAP (2026)
- Prédiction de la réfraction sous cycloplégie par apprentissage automatique avec l'Eyerobo Vision Screener : plan, une étude transversale comparative d'appareils (2026)
- Évaluer l'impact des lampes à fente portables assistées par IA sur les soins ophtalmologiques primaires en milieu rural (2025)
- Caractéristiques des paramètres biologiques et choix de la taille de la lentille en collamer implantable (ICL) dans les yeux myopes modérés, forts et très forts (2025)
- Exploration de modèles d'apprentissage automatique pour la sécurité du vault dans l'implantation d'ICL : une analyse comparative de modèles de régression et de classification (2025)