简体中文

← 论文

8 种人工晶状体生物测量公式的多重比较,包括机器学习薄透镜公式(MM)及内置眼前节光学相干断层扫描光线追踪公式

原文标题: A Multi Comparison of 8 Different Intraocular Lens Biometry Formulae, Including a Machine Learning Thin Lens Formula (MM) and an Inbuilt Anterior Segment Optical Coherence Tomography Ray Tracing Formula

Richard N. McNeely, Katherine McGinnity, Stephen Stewart, Emmanuel Eric Pazo, Salissou Moutari, Jonathan Edward Moore

Vision, 2024 · 期刊论文 · doi:10.3390/vision8030049 · 被引 3 次 · 开放获取(CC BY)

白内障与眼前节手术人工智能与深度学习

图文摘要. 准确性比较研究 · 100 只眼. ±0.75 D 以内比例,MM(单焦点): 96%; ±0.75 D 以内比例,SRK/T(多焦点): 94%. 包括较新的 MM 公式和光线追踪在内的 8 种人工晶状体度数公式均表现出很高的准确性。
图文摘要: SVG · PNG · JSON · 可在注明出处的前提下自由使用(CC BY 4.0)

要点速览

包括较新的 MM 公式和光线追踪在内的 8 种人工晶状体度数公式均表现出很高的准确性。

研究设计
准确性比较研究
样本
100 只眼
±0.75 D 以内比例,MM(单焦点)
96%
±0.75 D 以内比例,SRK/T(多焦点)
94%

摘要

本研究比较了人工晶状体(IOL)度数计算公式的准确性,包括 SRK/T、HofferQ、Holladay 1、Haigis、MM、Barrett Universal II(BUII)、Emmetropia Verifying Optical(EVO)以及 AS-OCT 光线追踪。研究纳入了 100 只植入 Rayone EMV RAO200E(Rayner Intraocular Lenses Limited,英国 Worthing)或 Artis Symbiose(Cristalens Industrie,法国 Lannion)IOL 的眼。使用 IOLMaster 700(Carl Zeiss Meditec AG,德国耶拿)和 MS-39 AS-OCT(CSO,意大利佛罗伦萨)获取生物测量数据。比较了平均绝对误差(MAE)、中位绝对误差(MedAE)以及在目标值 ±0.25D、±0.50D、±0.75D 和 ±1.00D 以内的眼所占百分比,其中 ±0.75D 被视为关键指标。对于增强型单焦点 IOL,±0.75D 以内比例最高的是 MM(96%),其次是 Haigis(94%)。对于多焦点 IOL,SRK/T(94%)的 ±0.75D 以内比例最高,其次是 Holladay 1、MM、BUII 和光线追踪(均为 90%)。两种 IOL 的 MAE 均无统计学显著差异。对于增强型单焦点 IOL,EVO 的 MAE 最低;对于多焦点 IOL,光线追踪的 MAE 最低。EVO 和光线追踪分别在两种 IOL 中显示出最低的 MedAE。各公式表现相近且准确性很高。MM 和光线追踪的准确性似乎与成熟公式相当,并显示出较高的 ±0.75D 以内眼比例。

译自英文原文摘要(许可协议:CC BY)。

显示英文原文摘要

A comparison of the accuracy of intraocular lens (IOL) power calculation formulae, including SRK/T, HofferQ, Holladay 1, Haigis, MM, Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO), and AS-OCT ray tracing, was performed. One hundred eyes implanted with either the Rayone EMV RAO200E (Rayner Intraocular Lenses Limited, Worthing, UK) or the Artis Symbiose (Cristalens Industrie, Lannion, France) IOL were included. Biometry was obtained using IOLMaster 700 (Carl Zeiss Meditec AG, Jena, Germany) and MS-39 AS-OCT (CSO, Firenze, Italy). Mean (MAE) and median (MedAE) absolute errors and percentage of eyes within ±0.25D, ±0.50D, ±0.75D, and ±1.00D of the target were compared, with ±0.75D considered a key metric. The highest percentage within ±0.75D was found with MM (96%) followed by the Haigis (94%) for the enhanced monofocal IOL. SRK/T (94%) had the highest percentage within ±0.75D, followed by Holladay 1, MM, BUII, and ray tracing (all 90%) for the multifocal IOL. No statistically significant difference in MAE was found with both IOLs. EVO showed the lowest MAE for the enhanced monofocal and ray tracing for the multifocal IOL. EVO and ray tracing showed the lowest MedAE for the two respective IOLs. A similar performance with high accuracy across formulae was found. MM and ray tracing appear to have similar accuracy to the well-established formulae and displayed a high percentage of eyes within ±0.75D.

关键词: intraocular lens power calculation; anterior segment optical coherence tomography; ray tracing; SRK/T formula; Haigis formula; Holladay 1 formula; Barrett Universal II formula; multifocal intraocular lens

获取全文

引用格式

McNeely, R. N., McGinnity, K., Stewart, S., Pazo, E. E., Moutari, S., Moore, J. E. (2024). A Multi Comparison of 8 Different Intraocular Lens Biometry Formulae, Including a Machine Learning Thin Lens Formula (MM) and an Inbuilt Anterior Segment Optical Coherence Tomography Ray Tracing Formula. Vision. https://doi.org/10.3390/vision8030049

显示 BibTeX
@article{mcneely2024a,
  title = {{A Multi Comparison of 8 Different Intraocular Lens Biometry Formulae, Including a Machine Learning Thin Lens Formula (MM) and an Inbuilt Anterior Segment Optical Coherence Tomography Ray Tracing Formula}},
  author = {McNeely, Richard N. and McGinnity, Katherine and Stewart, Stephen and Pazo, Emmanuel Eric and Moutari, Salissou and Moore, Jonathan Edward},
  journal = {Vision},
  year = {2024},
  doi = {10.3390/vision8030049},
  url = {https://doi.org/10.3390/vision8030049},
}

相关研究