Comparaison multiple de 8 formules biométriques de lentille intraoculaire, dont une formule de lentille mince par apprentissage automatique (MM) et une formule de tracé de rayons intégrée à une tomographie par cohérence optique du segment antérieur
Titre original : A Multi Comparison of 8 Different Intraocular Lens Biometry Formulae, Including a Machine Learning Thin Lens Formula (MM) and an Inbuilt Anterior Segment Optical Coherence Tomography Ray Tracing Formula
Richard N. McNeely, Katherine McGinnity, Stephen Stewart, Emmanuel Eric Pazo, Salissou Moutari, Jonathan Edward Moore
Cataracte et chirurgie du segment antérieurIA et apprentissage profond
En bref
Les huit formules de calcul d'implant, y compris les plus récentes MM et par tracé de rayons, ont toutes montré une grande exactitude.
- Type d'étude
- Étude comparative d'exactitude
- Échantillon
- 100 yeux
- À ±0.75 D, MM (monofocal)
- 96%
- À ±0.75 D, SRK/T (multifocal)
- 94%
Résumé
L'exactitude de formules de calcul de la puissance des lentilles intraoculaires (LIO), dont SRK/T, HofferQ, Holladay 1, Haigis, MM, Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO) et le tracé de rayons de l'AS-OCT, a été comparée. Cent yeux implantés avec la LIO Rayone EMV RAO200E (Rayner Intraocular Lenses Limited, Worthing, Royaume-Uni) ou l'Artis Symbiose (Cristalens Industrie, Lannion, France) ont été inclus. La biométrie a été obtenue avec l'IOLMaster 700 (Carl Zeiss Meditec AG, Iéna, Allemagne) et l'AS-OCT MS-39 (CSO, Florence, Italie). Les erreurs absolues moyenne (MAE) et médiane (MedAE) et le pourcentage d'yeux à ±0.25D, ±0.50D, ±0.75D et ±1.00D de la cible ont été comparés, ±0.75D étant considéré comme l'indicateur clé. Le plus fort pourcentage à ±0.75D a été obtenu avec MM (96 %), suivie de Haigis (94 %), pour la LIO monofocale améliorée. Pour la LIO multifocale, SRK/T (94 %) avait le plus fort pourcentage à ±0.75D, suivie de Holladay 1, MM, BUII et du tracé de rayons (tous 90 %). Aucune différence statistiquement significative de MAE n'a été trouvée pour les deux LIO. EVO a montré la MAE la plus faible pour la monofocale améliorée et le tracé de rayons pour la LIO multifocale. EVO et le tracé de rayons ont montré la MedAE la plus faible pour chacune des deux LIO. Des performances similaires et d'une grande exactitude ont été observées pour l'ensemble des formules. MM et le tracé de rayons semblent avoir une exactitude similaire à celle des formules établies et ont affiché un fort pourcentage d'yeux à ±0.75D.
Traduit du résumé original en anglais (licence : CC BY).
Afficher le résumé original
A comparison of the accuracy of intraocular lens (IOL) power calculation formulae, including SRK/T, HofferQ, Holladay 1, Haigis, MM, Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO), and AS-OCT ray tracing, was performed. One hundred eyes implanted with either the Rayone EMV RAO200E (Rayner Intraocular Lenses Limited, Worthing, UK) or the Artis Symbiose (Cristalens Industrie, Lannion, France) IOL were included. Biometry was obtained using IOLMaster 700 (Carl Zeiss Meditec AG, Jena, Germany) and MS-39 AS-OCT (CSO, Firenze, Italy). Mean (MAE) and median (MedAE) absolute errors and percentage of eyes within ±0.25D, ±0.50D, ±0.75D, and ±1.00D of the target were compared, with ±0.75D considered a key metric. The highest percentage within ±0.75D was found with MM (96%) followed by the Haigis (94%) for the enhanced monofocal IOL. SRK/T (94%) had the highest percentage within ±0.75D, followed by Holladay 1, MM, BUII, and ray tracing (all 90%) for the multifocal IOL. No statistically significant difference in MAE was found with both IOLs. EVO showed the lowest MAE for the enhanced monofocal and ray tracing for the multifocal IOL. EVO and ray tracing showed the lowest MedAE for the two respective IOLs. A similar performance with high accuracy across formulae was found. MM and ray tracing appear to have similar accuracy to the well-established formulae and displayed a high percentage of eyes within ±0.75D.
Mots-clés : intraocular lens power calculation; anterior segment optical coherence tomography; ray tracing; SRK/T formula; Haigis formula; Holladay 1 formula; Barrett Universal II formula; multifocal intraocular lens
Accès
Comment citer
Afficher le BibTeX
@article{mcneely2024a,
title = {{A Multi Comparison of 8 Different Intraocular Lens Biometry Formulae, Including a Machine Learning Thin Lens Formula (MM) and an Inbuilt Anterior Segment Optical Coherence Tomography Ray Tracing Formula}},
author = {McNeely, Richard N. and McGinnity, Katherine and Stewart, Stephen and Pazo, Emmanuel Eric and Moutari, Salissou and Moore, Jonathan Edward},
journal = {Vision},
year = {2024},
doi = {10.3390/vision8030049},
url = {https://doi.org/10.3390/vision8030049},
}
Travaux liés
- Prédiction de la réfraction sous cycloplégie par apprentissage automatique avec l'Eyerobo Vision Screener : plan, une étude transversale comparative d'appareils (2026)
- Exploration de modèles d'apprentissage automatique pour la sécurité du vault dans l'implantation d'ICL : une analyse comparative de modèles de régression et de classification (2025)
- Association des connaissances et des attitudes vis-à-vis du traitement anti-VEGF avec l'interruption autodéclarée du traitement : une étude de classification à séparation temporelle (2026)
- Mesure automatisée par apprentissage profond du volume de rétinoschisis et de décollement dans la myopie pathologique avec contraction sclérale postérieure (2026)
- Mesure et évaluation automatiques des structures anatomiques du segment antérieur sur des images UBM par une approche fondée sur l'apprentissage profond (2026)