基于深度学习的超声生物显微镜(UBM)图像眼前节解剖结构自动测量与评估
原文标题: Automatic measurement and evaluation of anterior segment anatomical structures via UBM images using a deep learning-based approach
S Chen, X Chu, EE Pazo, Y Huang, H Liu, C Zhang, R Yang, S Zhao
要点速览
YOLOv8-pose 模型在 UBM 图像上测量眼前节参数的准确度与经验丰富的临床医生相当,有助于 ICL 尺寸选择。
- 研究设计
- 横断面回顾性研究
- 样本
- 638 只眼
- 与参考标准的 ICC
- >0.978
- 平均相对误差
- <1.7%
- 分析的 UBM 图像数
- 1,480
摘要
本文摘要以原文(英文)显示,因为该文章未采用允许翻译的开放许可协议。
Purpose To develop a deep-learning model capable of measuring essential anterior segment (AS) parameters derived from preoperative ultrasound biomicroscopy (UBM) images of candidates for implantable collamer lens (ICL) surgery. Setting Tianjin Medical University Eye Hospital, Tianjin, China. Design Cross-sectional retrospective study. Methods A dataset comprising 1,480 preoperative panoramic UBM images taken from 638 eyes of 320 subjects was collected and was divided into training and testing subsets at a proportion of 7:3. Using the YOLOv8-pose algorithm, the model identified ten anatomical key point coordinates and computed six relevant AS parameters. Both manual and anterior segment optical coherence tomography-based non-contact measurements served as reference standards for evaluating the model's accuracy. The relationship between postoperative vault and preoperative parameters measured by the model was analyzed using multiple linear regression. Results On the test dataset, the model achieved an intraclass correlation coefficient (ICC) exceeding 0.978, with a mean Euclidean distance of 67.65 ± 54.25 μm across all point locations. The ICC values for anterior chamber depth (ACD), pupil diameter, and sulcus-to-sulcus distance were above 0.980 (95% CI: 0.975 to 0.985), with average relative error below 1.7%. Additionally, postoperative vault at one month was significantly correlated with model-measured parameters, including crystalline lens rise, iris concavity, and ACD (P Conclusion This study introduces a robust program capable of quantitatively measuring AS parameters with accuracy comparable to that of experienced ophthalmologists. The findings provide valuable guidance for ICL sizing and vault prediction.
获取全文
引用格式
显示 BibTeX
@article{chen2026automatic,
title = {{Automatic measurement and evaluation of anterior segment anatomical structures via UBM images using a deep learning-based approach}},
author = {Chen, S and Chu, X and Pazo, EE and Huang, Y and Liu, H and Zhang, C and Yang, R and Zhao, S},
journal = {Graefe's Archive for Clinical and Experimental Ophthalmology},
year = {2026},
doi = {10.1007/s00417-025-07070-7},
url = {https://doi.org/10.1007/s00417-025-07070-7},
}