日本語

← 論文

有水晶体眼内コラマーレンズ(ICL V4c)挿入後の瞳孔径が主観的視覚の質に及ぼす影響:観察研究

原題: The influence of pupil diameter upon and subjective quality of vision following implantable collamer lens (ICL V4c) implantation: An observational study

Qing Zhang, He Huang, Yi Wu, Guanghao Qin, Liangzhe Li, Jiayan Chen, Huixin Che, Tao Yao, Chunhong Yan, Ling Xu, Jonathan E Moore, Wei He, Sile Yu, Emmanuel Eric Pazo, Xingru He

Medicine, 2023 · 原著論文 · doi:10.1097/md.0000000000035198 · 被引用 10 回 · オープンアクセス(CC BY-NC)

白内障・前眼部手術

ビジュアルアブストラクト. 後ろ向き研究 · 53 眼. Rs(薄明視瞳孔とハロー): 0.624; 平均薄明視瞳孔径(mm): 6.59. ICL 手術後に瞳孔が大きいほど、特に夜間にハローが多く視覚の質が低い。
ビジュアルアブストラクト: SVG · PNG · JSON · 出典を明記すれば自由に再利用可(CC BY 4.0)

要点

ICL 手術後に瞳孔が大きいほど、特に夜間にハローが多く視覚の質が低い。

研究デザイン
後ろ向き研究
対象
53 眼
Rs(薄明視瞳孔とハロー)
0.624
平均薄明視瞳孔径(mm)
6.59

抄録

本研究は、有水晶体眼内コラマーレンズ(ICL)挿入者における瞳孔径の変化と、それが主観的視覚の質(QoV)に及ぼす影響を評価することを目的とした。本後ろ向き研究では、ICL(V4c)を挿入した参加者 53 人(53 眼)を評価し、瞳孔径に応じて段階的な群に分けた。術前・術後の明所視および薄明視の瞳孔径、裸眼遠見視力(UDVA)、QoV 質問票スコアを評価・比較した。術後 3 か月の UDVA は最小分離角の対数(LogMAR)で -0.10 ± 0.06 であり、日中と夜間の平均 QoV はそれぞれ 9.34 ± 0.76 と 8.58 ± 1.29 であった。平均薄明視瞳孔径と平均明所視瞳孔径はそれぞれ 6.59 ± 0.79 mm と 4.61 ± 0.74 mm であった。明所視瞳孔径は「日中の QoV」と負の相関(Rs = -0.413、P = .001)、「ハロー」(Rs = 0.568*、P < .001)および「かすみ」(Rs = 0.243、P = .04)と正の相関を示した。薄明視瞳孔径は「夜間の QoV」と負の相関(Rs = -0.426、P = .001)、「ハロー」(Rs = 0.624*、P < .001)、「スターバースト」(Rs = 0.233、P = .046)、「焦点の合わせにくさ」(Rs = 0.27、P = .025)と正の相関を示した。参加者は 3 か月の経過観察時に優れた視力を得ていた。明所視と薄明視の瞳孔径は、それぞれ日中と夜間の QoV スコアと負の相関を示した。瞳孔径は夜間の視覚症状により大きな影響を及ぼし、瞳孔が大きいことによる QoV の低下は夜間により顕著であった。ICL 挿入患者における瞳孔径の重要性と QoV への影響を探るため、さらなる研究が必要である。

英語の原文抄録からの翻訳です(ライセンス:CC BY-NC)。

原文の抄録を表示

This study aimed to assess the change in pupil size and its influence on subjective quality of vision (QoV) in subjects with implanted collamer lenses (ICLs). This retrospective study assessed 53 participants (53 eyes) implanted with ICL (V4c) and categorized them into incremental groups according to pupil diameter. Preoperative and postoperative photopic and mesopic pupil diameter, uncorrected distance visual acuity (UDVA), and QoV questionnaire scores were assessed and compared. Postoperatively, at 3 months, UDVA was -0.10 ± 0.06 logarithm of the minimum angle of resolution (LogMAR), and mean QoV for day and night was 9.34 ± 0.76 and 8.58 ± 1.29, respectively. The mean mesopic and photopic pupil diameters were 6.59 ± 0.79 mm and 4.61 ± 0.74 mm, respectively. Photopic pupil diameter negatively correlated with "QoV day" (Rs = -0.413, P = .001), positively correlated with "haloes" (Rs = 0.568*, P < .001) and "blurred vision" (Rs = 0.243, P = .04) respectively. Mesopic pupil diameter negatively correlated with "QoV night" (Rs = -0.426, P = .001), positively correlated with "haloes" (Rs = 0.624*, P < .001), "starburst" (Rs = 0.233, P = .046) and "difficulty focusing" (Rs = 0.27, P = .025), respectively. Participants had excellent VA at 3-month follow-up. Photopic and mesonic pupil diameter negatively correlated with QoV day and QoV night scores, respectively. Pupil diameter was found to have a more significant effect on visual symptoms at night, and lower QoV due to larger pupil size was more noticeable at night. Further investigation is needed to explore the importance of pupil diameter and its impact on the QoV in ICL implanted patients.

キーワード: implantable collamer lens; ICL V4c; pupil size; mesopic vision; photopic vision; night vision; HALOE; visual disturbances

アクセス

引用方法

Zhang, Q., Huang, H., Wu, Y., Qin, G., Li, L., Chen, J., Che, H., Yao, T., Yan, C., Xu, L., Moore, J. E., He, W., Yu, S., Pazo, E. E., He, X. (2023). The influence of pupil diameter upon and subjective quality of vision following implantable collamer lens (ICL V4c) implantation: An observational study. Medicine. https://doi.org/10.1097/md.0000000000035198

BibTeX を表示
@article{zhang2023the,
  title = {{The influence of pupil diameter upon and subjective quality of vision following implantable collamer lens (ICL V4c) implantation: An observational study}},
  author = {Zhang, Qing and Huang, He and Wu, Yi and Qin, Guanghao and Li, Liangzhe and Chen, Jiayan and Che, Huixin and Yao, Tao and Yan, Chunhong and Xu, Ling and Moore, Jonathan E and He, Wei and Yu, Sile and Pazo, Emmanuel Eric and He, Xingru},
  journal = {Medicine},
  year = {2023},
  doi = {10.1097/md.0000000000035198},
  url = {https://doi.org/10.1097/md.0000000000035198},
}

関連する論文