简体中文

← 论文

瞳孔直径对植入式胶原晶状体(ICL V4c)植入术后主观视觉质量的影响:一项观察性研究

原文标题: The influence of pupil diameter upon and subjective quality of vision following implantable collamer lens (ICL V4c) implantation: An observational study

Qing Zhang, He Huang, Yi Wu, Guanghao Qin, Liangzhe Li, Jiayan Chen, Huixin Che, Tao Yao, Chunhong Yan, Ling Xu, Jonathan E Moore, Wei He, Sile Yu, Emmanuel Eric Pazo, Xingru He

Medicine, 2023 · 期刊论文 · doi:10.1097/md.0000000000035198 · 被引 10 次 · 开放获取(CC BY-NC)

白内障与眼前节手术

图文摘要. 回顾性研究 · 53 只眼. Rs(中间视瞳孔与光晕): 0.624; 平均中间视瞳孔直径(mm): 6.59. ICL 术后瞳孔越大,光晕越多、视觉质量越低,夜间尤为明显。
图文摘要: SVG · PNG · JSON · 可在注明出处的前提下自由使用(CC BY 4.0)

要点速览

ICL 术后瞳孔越大,光晕越多、视觉质量越低,夜间尤为明显。

研究设计
回顾性研究
样本
53 只眼
Rs(中间视瞳孔与光晕)
0.624
平均中间视瞳孔直径(mm)
6.59

摘要

本研究旨在评估植入式胶原晶状体(ICL)植入者瞳孔大小的变化及其对主观视觉质量(QoV)的影响。这项回顾性研究评估了 53 名植入 ICL(V4c)的参与者(53 只眼),并按瞳孔直径将其分为递增的组别。评估并比较了术前和术后的明视及中间视瞳孔直径、裸眼远视力(UDVA)和 QoV 问卷评分。术后 3 个月时,UDVA 为 -0.10 ± 0.06 最小分辨角对数(LogMAR),白天和夜间的平均 QoV 分别为 9.34 ± 0.76 和 8.58 ± 1.29。平均中间视瞳孔直径和明视瞳孔直径分别为 6.59 ± 0.79 mm 和 4.61 ± 0.74 mm。明视瞳孔直径与“白天 QoV”呈负相关(Rs = -0.413,P = .001),与“光晕”(Rs = 0.568*,P < .001)和“视物模糊”(Rs = 0.243,P = .04)呈正相关。中间视瞳孔直径与“夜间 QoV”呈负相关(Rs = -0.426,P = .001),与“光晕”(Rs = 0.624*,P < .001)、“星芒”(Rs = 0.233,P = .046)和“对焦困难”(Rs = 0.27,P = .025)呈正相关。参与者在 3 个月随访时视力极佳。明视和中间视瞳孔直径分别与白天 QoV 和夜间 QoV 评分呈负相关。瞳孔直径对夜间视觉症状的影响更为显著,瞳孔较大导致的 QoV 下降在夜间更为明显。需要进一步研究以探讨瞳孔直径的重要性及其对 ICL 植入患者 QoV 的影响。

译自英文原文摘要(许可协议:CC BY-NC)。

显示英文原文摘要

This study aimed to assess the change in pupil size and its influence on subjective quality of vision (QoV) in subjects with implanted collamer lenses (ICLs). This retrospective study assessed 53 participants (53 eyes) implanted with ICL (V4c) and categorized them into incremental groups according to pupil diameter. Preoperative and postoperative photopic and mesopic pupil diameter, uncorrected distance visual acuity (UDVA), and QoV questionnaire scores were assessed and compared. Postoperatively, at 3 months, UDVA was -0.10 ± 0.06 logarithm of the minimum angle of resolution (LogMAR), and mean QoV for day and night was 9.34 ± 0.76 and 8.58 ± 1.29, respectively. The mean mesopic and photopic pupil diameters were 6.59 ± 0.79 mm and 4.61 ± 0.74 mm, respectively. Photopic pupil diameter negatively correlated with "QoV day" (Rs = -0.413, P = .001), positively correlated with "haloes" (Rs = 0.568*, P < .001) and "blurred vision" (Rs = 0.243, P = .04) respectively. Mesopic pupil diameter negatively correlated with "QoV night" (Rs = -0.426, P = .001), positively correlated with "haloes" (Rs = 0.624*, P < .001), "starburst" (Rs = 0.233, P = .046) and "difficulty focusing" (Rs = 0.27, P = .025), respectively. Participants had excellent VA at 3-month follow-up. Photopic and mesonic pupil diameter negatively correlated with QoV day and QoV night scores, respectively. Pupil diameter was found to have a more significant effect on visual symptoms at night, and lower QoV due to larger pupil size was more noticeable at night. Further investigation is needed to explore the importance of pupil diameter and its impact on the QoV in ICL implanted patients.

关键词: implantable collamer lens; ICL V4c; pupil size; mesopic vision; photopic vision; night vision; HALOE; visual disturbances

获取全文

引用格式

Zhang, Q., Huang, H., Wu, Y., Qin, G., Li, L., Chen, J., Che, H., Yao, T., Yan, C., Xu, L., Moore, J. E., He, W., Yu, S., Pazo, E. E., He, X. (2023). The influence of pupil diameter upon and subjective quality of vision following implantable collamer lens (ICL V4c) implantation: An observational study. Medicine. https://doi.org/10.1097/md.0000000000035198

显示 BibTeX
@article{zhang2023the,
  title = {{The influence of pupil diameter upon and subjective quality of vision following implantable collamer lens (ICL V4c) implantation: An observational study}},
  author = {Zhang, Qing and Huang, He and Wu, Yi and Qin, Guanghao and Li, Liangzhe and Chen, Jiayan and Che, Huixin and Yao, Tao and Yan, Chunhong and Xu, Ling and Moore, Jonathan E and He, Wei and Yu, Sile and Pazo, Emmanuel Eric and He, Xingru},
  journal = {Medicine},
  year = {2023},
  doi = {10.1097/md.0000000000035198},
  url = {https://doi.org/10.1097/md.0000000000035198},
}

相关研究