日本語

← 論文

回転非対称屈折型多焦点眼内レンズの両眼対称の鼻下側近用加入と、鼻下側・耳上側配置との視機能および視覚の質の比較

原題: Comparison of the visual performance and quality of vision with combined symmetrical inferonasal near addition versus inferonasal and superotemporal placement of rotationally asymmetric refractive multifocal intraocular lenses

Richard N. McNeely, Emmanuel Eric Pazo, Andrew Spence, Olivier Richoz, Andrew M. Nesbit, Tara Moore, Jonathan Edward Moore

Journal of Cataract & Refractive Surgery, 2016 · 原著論文 · doi:10.1016/j.jcrs.2016.10.016 · 被引用 27 回

白内障・前眼部手術

ビジュアルアブストラクト. 後ろ向き比較症例集積 · 患者 180 人(360 眼). 加入部(耳上側、優位眼): +2.00; 加入部(鼻下側、僚眼): +3.00. 左右眼で近用部の配置を変えると、非対称多焦点 IOL で最も良好な視覚の質が得られた。
ビジュアルアブストラクト: SVG · PNG · JSON · 出典を明記すれば自由に再利用可(CC BY 4.0)

要点

左右眼で近用部の配置を変えると、非対称多焦点 IOL で最も良好な視覚の質が得られた。

研究デザイン
後ろ向き比較症例集積
対象
患者 180 人(360 眼)
加入部(耳上側、優位眼)
+2.00
加入部(鼻下側、僚眼)
+3.00

抄録

この抄録は原語(英語)で表示しています。論文が翻訳を認めるオープンライセンスで公開されていないためです。

PURPOSE: To compare the postoperative quality of vision between different bilateral placements of near segments of rotationally asymmetric refractive multifocal intraocular lenses (IOLs) and to determine how this affects visual performance. SETTING: Cathedral Eye Clinic, Belfast, Northern Ireland, United Kingdom. DESIGN: Retrospective comparative case series. METHODS: The study enrolled consecutive patients having refractive lens exchange and implantation of rotationally asymmetric multifocal IOLs. Group 1 received bilateral SBL-3 IOLs and Group 2 received bilateral Lentis Mplus LS-312 MF30 IOLs, with the near segments placed inferonasally in each group. Group 3 received a Lentis Mplus LS-312 MF20 IOL in the dominant eye with the near segment positioned superotemporal and a Lenstec SBL-3 IOL positioned inferonasally in the fellow eye. Binocular uncorrected (UDVA) and corrected distance visual acuities, binocular uncorrected near (UNVA) and intermediate (UIVA) visual acuities, binocular distance-corrected near and intermediate visual acuities, and quality of vision were evaluated over 3 months postoperatively. RESULTS: The study enrolled 180 patients (360 eyes). There was no significant difference between the groups in binocular UDVA, UIVA, and UNVA; however, there was a significant difference between the groups in quality of vision (P ≤ .001). Group 3 had significantly better overall quality of vision. CONCLUSION: When implanting rotationally asymmetric multifocal IOLs, a combination of superotemporal placement of the near segment (+2.00 diopter [D] addition [add]) in the dominant eye with inferonasal placement of the near segment (+3.00 D add) in the fellow eye yielded consistent, high overall quality of vision and uncorrected visual acuity. FINANCIAL DISCLOSURE: None of the authors has a financial or proprietary interest in any material or method mentioned.

キーワード: refractive lens exchange; visual quality; visual performance; uncorrected visual acuity; intermediate vision

アクセス

引用方法

McNeely, R. N., Pazo, E. E., Spence, A., Richoz, O., Nesbit, A. M., Moore, T., Moore, J. E. (2016). Comparison of the visual performance and quality of vision with combined symmetrical inferonasal near addition versus inferonasal and superotemporal placement of rotationally asymmetric refractive multifocal intraocular lenses. Journal of Cataract & Refractive Surgery. https://doi.org/10.1016/j.jcrs.2016.10.016

BibTeX を表示
@article{mcneely2016comparison,
  title = {{Comparison of the visual performance and quality of vision with combined symmetrical inferonasal near addition versus inferonasal and superotemporal placement of rotationally asymmetric refractive multifocal intraocular lenses}},
  author = {McNeely, Richard N. and Pazo, Emmanuel Eric and Spence, Andrew and Richoz, Olivier and Nesbit, Andrew M. and Moore, Tara and Moore, Jonathan Edward},
  journal = {Journal of Cataract & Refractive Surgery},
  year = {2016},
  doi = {10.1016/j.jcrs.2016.10.016},
  url = {https://doi.org/10.1016/j.jcrs.2016.10.016},
}

関連する論文