旋转非对称折射型多焦点人工晶状体双眼对称鼻下方近附加与鼻下方/颞上方组合放置的视功能及视觉质量比较

原文标题: Comparison of the visual performance and quality of vision with combined symmetrical inferonasal near addition versus inferonasal and superotemporal placement of rotationally asymmetric refractive multifocal intraocular lenses

Richard N. McNeely, Emmanuel Eric Pazo, Andrew Spence, Olivier Richoz, Andrew M. Nesbit, Tara Moore, Jonathan Edward Moore

Journal of Cataract & Refractive Surgery, 2016 · 期刊论文 · doi:10.1016/j.jcrs.2016.10.016 · 被引 27 次

白内障与眼前节手术

图文摘要. 回顾性比较病例系列 · 180 例患者(360 只眼). 附加区位于颞上方(主视眼): +2.00; 附加区位于鼻下方(对侧眼): +3.00. 双眼采用不同近用区放置方式,非对称多焦点人工晶状体的视觉质量最佳。
图文摘要: SVG · PNG · JSON · 可在注明出处的前提下自由使用(CC BY 4.0)

要点速览

双眼采用不同近用区放置方式,非对称多焦点人工晶状体的视觉质量最佳。

研究设计
回顾性比较病例系列
样本
180 例患者(360 只眼)
附加区位于颞上方(主视眼)
+2.00
附加区位于鼻下方(对侧眼)
+3.00

摘要

本文摘要以原文(英文)显示,因为该文章未采用允许翻译的开放许可协议。

PURPOSE: To compare the postoperative quality of vision between different bilateral placements of near segments of rotationally asymmetric refractive multifocal intraocular lenses (IOLs) and to determine how this affects visual performance. SETTING: Cathedral Eye Clinic, Belfast, Northern Ireland, United Kingdom. DESIGN: Retrospective comparative case series. METHODS: The study enrolled consecutive patients having refractive lens exchange and implantation of rotationally asymmetric multifocal IOLs. Group 1 received bilateral SBL-3 IOLs and Group 2 received bilateral Lentis Mplus LS-312 MF30 IOLs, with the near segments placed inferonasally in each group. Group 3 received a Lentis Mplus LS-312 MF20 IOL in the dominant eye with the near segment positioned superotemporal and a Lenstec SBL-3 IOL positioned inferonasally in the fellow eye. Binocular uncorrected (UDVA) and corrected distance visual acuities, binocular uncorrected near (UNVA) and intermediate (UIVA) visual acuities, binocular distance-corrected near and intermediate visual acuities, and quality of vision were evaluated over 3 months postoperatively. RESULTS: The study enrolled 180 patients (360 eyes). There was no significant difference between the groups in binocular UDVA, UIVA, and UNVA; however, there was a significant difference between the groups in quality of vision (P ≤ .001). Group 3 had significantly better overall quality of vision. CONCLUSION: When implanting rotationally asymmetric multifocal IOLs, a combination of superotemporal placement of the near segment (+2.00 diopter [D] addition [add]) in the dominant eye with inferonasal placement of the near segment (+3.00 D add) in the fellow eye yielded consistent, high overall quality of vision and uncorrected visual acuity. FINANCIAL DISCLOSURE: None of the authors has a financial or proprietary interest in any material or method mentioned.

关键词: refractive lens exchange; visual quality; visual performance; uncorrected visual acuity; intermediate vision

获取全文

引用格式

McNeely, R. N., Pazo, E. E., Spence, A., Richoz, O., Nesbit, A. M., Moore, T., Moore, J. E. (2016). Comparison of the visual performance and quality of vision with combined symmetrical inferonasal near addition versus inferonasal and superotemporal placement of rotationally asymmetric refractive multifocal intraocular lenses. Journal of Cataract & Refractive Surgery. https://doi.org/10.1016/j.jcrs.2016.10.016

显示 BibTeX
@article{mcneely2016comparison,
  title = {{Comparison of the visual performance and quality of vision with combined symmetrical inferonasal near addition versus inferonasal and superotemporal placement of rotationally asymmetric refractive multifocal intraocular lenses}},
  author = {McNeely, Richard N. and Pazo, Emmanuel Eric and Spence, Andrew and Richoz, Olivier and Nesbit, Andrew M. and Moore, Tara and Moore, Jonathan Edward},
  journal = {Journal of Cataract & Refractive Surgery},
  year = {2016},
  doi = {10.1016/j.jcrs.2016.10.016},
  url = {https://doi.org/10.1016/j.jcrs.2016.10.016},
}

相关研究