Evaluación de los efectos de las lágrimas artificiales sobre los parámetros biológicos oculares en pacientes con y sin ojo seco
Título original: To evaluate the effects of artificial tears on ocular biological parameters in dry eye and non-dry eye patients
Yimeng Chen, Mingze Li, Jiayan Chen, Jiahui Zhao, Emmanuel Eric Pazo, Guanghao Qin, Xingru He
De un vistazo
Las lágrimas artificiales alteran las lecturas de longitud axial y espesor corneal; espere al menos 5 minutos antes de la biometría.
- Diseño
- Estudio prospectivo
- Muestra
- 98 ojos
- Espera recomendada tras las gotas
- 5 min
- Cambio del ECC en todos los tiempos
- p < 0.001
Resumen
Este resumen se muestra en su idioma original, el inglés, porque la licencia del artículo (CC BY-NC-ND) no permite publicar traducciones.
To analyze the changes in ocular biometry readings in patients with dry eye (DE) and non-dry eye (NDE) after instilling artificial tear drop (ATD). A prospective study was conducted on 98 eyes of 98 patients (DE group, n = 54 eyes; NDE group, n = 44 eyes) who underwent ocular biometry with four consecutive measurements using the IOL Master 700. The baseline flat meridian of the anterior corneal surface (K1), steep meridian of the anterior corneal surface (K2), corneal curvature radius(R1, R2), axial length (AL), anterior chamber depth (ACD), central corneal thickness (CCT), white-to-white corneal diameter (WTW), pupil diameter, non-invasive tear break-up time (NITBUT) and tear meniscus height, (TMH) was measured at baseline, 30-s, 2-min, and 5-min intervals after instilling one drop of ATD. Variability in biometry measurements was assessed and compared. The mean age of the NDE group and DE group was 27.09 ± 10.21 years (30 females, 68.18%) and 29.96 ± 12.08 years (38 females, 70.37%), respectively. Following the application of ATD, intergroup comparisons revealed significant changes in K1 at 2 min and 5 min (p = 0.043, p = 0.043, and p = 0.038, respectively), and significant changes in R1 and R2 at 2 min. Intragroup comparisons showed that AL exhibited significant changes at 30 s (p < 0.001), while CCT demonstrated significant alterations across all time points (p < 0.001). Changes in ACD were observed at 30 s and 2 min in the dry eye group, and pupil diameter showed significant changes at 2 min in both the DE and NDE groups. No significant changes were detected in WTW at any point (all p > 0.05). Artificial tears significantly affect the readings of AL and CCT during ocular biometry. It is recommended to wait for at least 5 min after the installation of eye drops before performing ocular biometry measurements.
Palabras clave: artificial tears; dry eye; ocular biometry; axial length; central corneal thickness; anterior chamber depth; corneal curvature; pupil size
Acceso
Cómo citar
Mostrar BibTeX
@article{chen2025to,
title = {{To evaluate the effects of artificial tears on ocular biological parameters in dry eye and non-dry eye patients}},
author = {Chen, Yimeng and Li, Mingze and Chen, Jiayan and Zhao, Jiahui and Pazo, Emmanuel Eric and Qin, Guanghao and He, Xingru},
journal = {Scientific Reports},
year = {2025},
doi = {10.1038/s41598-025-95801-5},
url = {https://doi.org/10.1038/s41598-025-95801-5},
}
Trabajos relacionados
- Análisis de la influencia del espacio del margen del colgajo en la regeneración de los nervios corneales tras LASIK asistido por láser de femtosegundo (2026)
- Comparación entre el efecto de la luz pulsada intensa y la higiene palpebral sobre la película lagrimal y la superficie ocular: un estudio controlado aleatorizado (2026)
- Effects of 3% diquafosol sodium on tear film stability, corneal aberration parameters, and vision-related quality of life in pediatric orthokeratology-associated dry eye disease (2026)
- Asociación entre el índice de masa corporal materno previo al embarazo y el astigmatismo y la curvatura corneal de la descendencia: un estudio transversal (2025)
- Expresión diferencial de linfotoxina α, inmunoglobulina E y metaloproteinasa de matriz 9 en lágrimas en el ojo seco asociado a conjuntivitis alérgica (2025)