Facogoniosinequiólisis frente a facotrabeculectomía en pacientes con glaucoma primario de ángulo cerrado refractario: un estudio comparativo
Título original: Phaco-goniosynechialysis versus phaco-trabeculectomy in patients with refractory primary angle-closure glaucoma: a comparative study
Jiahui Zhao, Chenguang Zhang, Emmanuel Eric Pazo, Guangzheng Dai, Yunyan Li, Yimeng Chen, Mingze Li, Huixin Che
Cataratas y cirugía del segmento anterior
De un vistazo
La facoemulsificación con goniosinequiólisis es tan segura y eficaz como la facotrabeculectomía en el GPAC refractario, con mejor visión referida por el paciente.
- Diseño
- Estudio comparativo retrospectivo
- Muestra
- 77 ojos
- NEI VFQ-25, faco + GSL
- 74.47
- NEI VFQ-25, faco + trab
- 69.57
Resumen
OBJETIVO: Comparar los efectos de la facoemulsificación con implante de lente intraocular (faco) combinada con goniosinequiólisis (faco + GSL) frente a la faco con trabeculectomía (faco + trab) en el tratamiento del glaucoma primario de ángulo cerrado (GPAC) refractario con sinequias anteriores periféricas (SAP) de más de 180°. MÉTODOS: Este estudio retrospectivo siguió 77 ojos de 77 pacientes durante al menos 6 meses. La presión intraocular (PIO), la mejor agudeza visual corregida (MAVC), el número de fármacos antiglaucomatosos y las SAP se registraron en la situación basal preoperatoria y se evaluaron en cada visita de seguimiento posoperatoria. Se administró a los pacientes incluidos el National Eye Institute Visual Functioning Questionnaire-25 (NEI VFQ-25). Se realizaron un análisis de correlación de Pearson y un análisis lineal multivariante para identificar los factores que influyen en los cambios de las puntuaciones del NEI VFQ-25 y los factores asociados a su aumento tras la intervención. RESULTADOS: En total se incluyeron setenta y siete ojos (43 con faco + GSL y 34 con faco + trab). La comparación entre la situación basal preoperatoria y las mediciones del mes 6 tras la cirugía mostró que ambos grupos presentaron mejoras significativas de la PIO, las SAP, la MAVC y el número de fármacos antiglaucomatosos (P < 0.05). Las puntuaciones basales del NEI VFQ-25 fueron similares en ambos grupos, pero hubo una diferencia significativa en las puntuaciones posoperatorias (74.47 ± 10.39 con faco + GSL frente a 69.57 ± 8.54 con faco + trab, P = 0.048 < 0.05), y el grupo faco + GSL obtuvo mejores puntuaciones en la última visita de seguimiento. El cambio de las puntuaciones preoperatorias y el número de fármacos antiglaucomatosos se correlacionaron significativamente con las puntuaciones posoperatorias en el grupo faco + GSL. CONCLUSIÓN: El tratamiento con faco + GSL es tan seguro y eficaz como la faco + trab en los pacientes con GPAC refractario, y la experiencia subjetiva de los pacientes mejoró significativamente tras la cirugía de faco + GSL.
Traducido del resumen original en inglés (licencia: CC BY).
Mostrar el resumen original
PURPOSE: To compare the effects of phacoemulsification with intraocular lens implantation (phaco) combined with goniosynechialysis (phaco + GSL) versus phaco with trabeculectomy (phaco + trab) for the management of primary angle-closure glaucoma (PACG) refractory to peripheral anterior synechiae (PAS) of over 180°. METHODS: This retrospective study followed 77 eyes of 77 patients for at least 6 months. Intraocular pressure (IOP), best-corrected visual acuity (BCVA), number of glaucoma drugs, and PAS were recorded at the preoperative baseline and evaluated at each postoperative follow-up visit. The National Eye Institute Visual Functioning Questionnaire-25 (NEI VFQ-25) was administered to patients enrolled in this study. Pearson's correlation analysis and multivariate linear analysis were performed to identify factors influencing changes in NEI VFQ-25 scores and to identify factors associated with increases in NEI VFQ-25 scores after the operation. RESULTS: In total, seventy-seven eyes were included (43 with phaco + GSL and 34 with phaco + trab). Comparing preoperative baseline and month 6 after surgery measurements revealed that both groups found significant improvements in IOP, PAS, BCVA and the number of glaucoma drugs (P < 0.05). Baseline NEI VFQ-25 scores were similar in the two groups, but there was a significant difference in postoperative NEI VFQ-25 scores (74.47 ± 10.39 in phaco + GSL vs. 69.57 ± 8.54 in phaco + trab, P = 0.048 < 0.05), and the phaco + GSL group had better scores at the time of the last follow-up. The change in preoperative scores and the number of glaucoma drugs was significantly correlated with postoperative scores in the phaco + GSL group. CONCLUSION: Phaco + GSL treatment is as safe and effective as phaco + trab for refractory PACG patients, and patients' subjective experience improved significantly after phaco + GSL surgery.
Palabras clave: primary angle-closure glaucoma; refractory glaucoma; phacoemulsification; goniosynechialysis; trabeculectomy; peripheral anterior synechiae; intraocular pressure; visual function
Acceso
Cómo citar
Mostrar BibTeX
@article{zhao2023phaco,
title = {{Phaco-goniosynechialysis versus phaco-trabeculectomy in patients with refractory primary angle-closure glaucoma: a comparative study}},
author = {Zhao, Jiahui and Zhang, Chenguang and Pazo, Emmanuel Eric and Dai, Guangzheng and Li, Yunyan and Chen, Yimeng and Li, Mingze and Che, Huixin},
journal = {BMC Ophthalmology},
year = {2023},
doi = {10.1186/s12886-023-02885-6},
url = {https://doi.org/10.1186/s12886-023-02885-6},
}
Trabajos relacionados
- Adherencia al seguimiento a largo plazo tras el implante de lente de colámero implantable en pacientes con miopía alta: un estudio unicéntrico de cohorte retrospectiva y encuesta CAP (2026)
- Predicción de la refracción ciclopléjica basada en aprendizaje automático con el Eyerobo Vision Screener: diseño, un estudio transversal comparativo de dispositivos (2026)
- Evaluación del impacto de las lámparas de hendidura portátiles asistidas por IA en la atención oftalmológica primaria rural (2025)
- Características de los parámetros biológicos y selección del tamaño de la lente de colámero implantable (ICL) en ojos con miopía moderada, alta y muy alta (2025)
- Exploración de modelos de aprendizaje automático para la seguridad del vault en el implante de ICL: un análisis comparativo de modelos de regresión y de clasificación (2025)