基于单次筛查数据预测儿童近视进展:一项多结局模型开发与验证研究
原文标题: Predicting pediatric myopia progression from single screening encounters: a multi-outcome development and validation study
Nan Wei, Chaoran Li, Salissou Moutari, Muhammad Usama, Jing Li, Qiaoyan Chen, Emmanuel Eric Pazo, Xuehan Qian
要点速览
仅使用年龄、性别和屈光度的简单模型即可预测儿童高度近视;筛查设备的生物测量参数没有额外价值。
- 研究设计
- 预测模型开发(TRIPOD+AI)
- 样本
- 2,373 名儿童
- AUC(1 年高度近视)
- 0.878
- 灵敏度(2 年模型)
- 83.4%
- 阴性预测值
- 97.1%
查看 5 张图表中的结果 ↓ 数据下载: CSV · JSON
摘要
本文摘要以原文(英文)显示,因为该文章的许可协议(CC BY-NC-ND)不允许发布译文。
Pediatric myopia screening captures refractive and biometric measurements but rarely converts them into individualised risk estimates. Whether automated biometric features (pupil diameter, interpupil distance, gaze deviation) add predictive value beyond standard refraction is unevaluated. We developed and internally validated a calibrated multi-outcome risk model using 4,220 screening records from 2,373 children (ages 6–13) from 2018 to 2021. Six outcomes were predicted: high myopia (spherical equivalent $$\:\le\:-3.00$$ D) at 1, 2 and 3 years, mild-to-moderate progression, myopia onset, and rapid progression. Progressively richer feature tiers were compared with patient-grouped cross-validation, patient-clustered bootstrap, DeLong tests with Holm-Bonferroni correction, temporal validation, six comparators, and a pre-specified sex-stratified fairness assessment. Reporting followed TRIPOD + AI. The clinical refraction model (age, sex, spherical equivalent) achieved AUC 0.878 (95% CI 0.815–0.931) for 1-year high myopia, 0.828 at 2 years and 0.795 at 3 years; mild-to-moderate progression reached 0.782 and onset 0.739. Temporal validation preserved discrimination, and no comparator was significantly superior. Biometric features added no discrimination on any outcome, no single feature changing AUC beyond 0.005. After isotonic recalibration, decision curve analysis showed net benefit; at a 30% threshold the 2-year model reached 83.4% sensitivity and 97.1% negative predictive value, without disparity by sex. A parsimonious logistic regression model using only routine screening data predicts pediatric high myopia across multiple horizons. Screening-device biometric features add no incremental value, being correlated with the dominant age and refractive predictors.
关键词: childhood myopia; myopia progression; myopia screening; risk prediction model; pupil size; gaze deviation; biometric traits; refractive error
图表解读
5 张图表 · 约 3 分钟阅读
常规学龄期眼部筛查会记录屈光度,较新的设备还会自动测量瞳孔大小、瞳距和注视偏斜等生物学参数。本研究探讨仅凭一次筛查能否预测哪些儿童会在一至三年内发展为高度近视(等效球镜 −3.00 D 或更差),以及这些设备生物学参数是否有帮助。模型基于 2018 年至 2021 年间收集的 2,373 名 6–13 岁儿童的 4,220 条筛查记录建立。以下五张图表均根据论文已发表的表格绘制。
1. 六个结局,从罕见到常见
模型预测六个结局。1 年内高度近视并不常见(1,039 条基线记录中占 5.5%),随时间延长逐渐增多,3 年内达到 15.2%。尚未近视的儿童中有 33.2% 发生近视,已近视的儿童中有 70.3% 出现快速进展(每年加深 0.50 D 或以上)。
数据表
| 结局 | 事件发生率(%) |
|---|---|
| 1 年高度近视 | 5.5 |
| 2 年高度近视 | 9.7 |
| 3 年高度近视 | 15.2 |
| 轻中度进展 | 36.3 |
| 近视发生 | 33.2 |
| 快速进展 | 70.3 |
2. 年龄、性别和屈光度起主要作用
在人口学特征基础上加入屈光测量(T2 层:年龄、性别和等效球镜)后,1 年高度近视的 AUC 从 0.688 升至 0.878,2 年为 0.828,3 年为 0.795。加入屈光力矢量(T3)或筛查设备的生物学特征(T4)后,任何时间范围的高度近视、轻中度进展或近视发生的 AUC 均未提高。唯一的例外是快速进展,加入生物学参数后从 0.566 升至 0.617;但由于该增益的置信区间跨越零,作者将其视为探索性结果。
数据表
| 结局 | T1:人口学特征 (95% CI) | T2:+ 临床屈光 (95% CI) | T3:+ 屈光力矢量 (95% CI) | T4:+ 生物学参数 (95% CI) |
|---|---|---|---|---|
| 1 年高度近视 | 0.688 [0.620, 0.751] | 0.878 [0.815, 0.931] | 0.862 [0.798, 0.918] | 0.849 [0.782, 0.909] |
| 2 年高度近视 | 0.635 [0.587, 0.680] | 0.828 [0.783, 0.869] | 0.824 [0.780, 0.866] | 0.816 [0.771, 0.859] |
| 3 年高度近视 | 0.598 [0.562, 0.636] | 0.795 [0.761, 0.827] | 0.786 [0.750, 0.821] | 0.791 [0.758, 0.824] |
| 轻中度进展 | 0.495 [0.436, 0.556] | 0.782 [0.733, 0.829] | 0.764 [0.711, 0.813] | 0.755 [0.701, 0.806] |
| 近视发生 | 0.628 [0.597, 0.656] | 0.739 [0.714, 0.764] | 0.732 [0.706, 0.758] | 0.733 [0.707, 0.759] |
| 快速进展 | 0.549 [0.482, 0.611] | 0.566 [0.503, 0.633] | 0.587 [0.522, 0.648] | 0.617 [0.556, 0.677] |
3. 简单模型同样出色
在 2 年预测任务中,所提出的 T2 logistic 回归模型(AUC 0.828)与六种替代方法进行了比较,均未显著优于该模型。基于年龄和屈光度的简单阈值规则得分为 0.838。使用全部特征的树模型 Random Forest、XGBoost 和 LightGBM 分别为 0.813、0.779 和 0.774,复现的 Lin et al. 2018 模型为 0.794。
数据表
| 方法 | AUC (95% CI) |
|---|---|
| 临床阈值规则 | 0.838 [0.798, 0.876] |
| 所提出的 T2(本研究) | 0.828 [0.783, 0.869] |
| 所提出的 T4(+ 生物学参数) | 0.816 [0.771, 0.859] |
| Random Forest | 0.813 [0.767, 0.854] |
| Lin et al. 2018 (Random Forest) | 0.794 [0.745, 0.840] |
| XGBoost | 0.779 [0.731, 0.826] |
| LightGBM | 0.774 [0.725, 0.821] |
4. 在后续年份中依然稳健
为模拟真实应用,模型以 2018–2019 年的记录重新拟合,并在从未见过的 2020–2021 年记录上测试。1、2、3 年的 AUC 分别为 0.814、0.804 和 0.796,交叉验证中分别为 0.878、0.828 和 0.795。由于每个时间测试集仅含 14 个事件,置信区间较宽。
数据表
| 时间范围 | 交叉验证 (95% CI) | 时间测试(2020–21) (95% CI) |
|---|---|---|
| 1 年高度近视 | 0.878 [0.815, 0.931] | 0.814 [0.661, 0.925] |
| 2 年高度近视 | 0.828 [0.783, 0.869] | 0.804 [0.648, 0.922] |
| 3 年高度近视 | 0.795 [0.761, 0.827] | 0.796 [0.633, 0.920] |
5. 选择风险阈值
使用该模型需要选定一个风险阈值。在预先设定的 30% 阈值下,模型识别出了 83.4% 后来发展为 2 年高度近视的儿童(灵敏度),特异度为 58.5%,阴性预测值为 97.1%。被标记的儿童中有 17.7% 发展为高度近视,而整个队列的基础发生率为 9.7%。
数据表
| 阈值 | 灵敏度 | 特异度 | NPV |
|---|---|---|---|
| 0.05 | 99.3% | 2.1% | 96.7% |
| 0.10 | 98.7% | 5.3% | 97.4% |
| 0.15 | 96.0% | 12.9% | 96.8% |
| 0.20 | 94.0% | 25.7% | 97.6% |
| 0.25 | 86.8% | 42.9% | 96.8% |
| 0.30 | 83.4% | 58.5% | 97.1% |
| 0.40 | 74.2% | 78.6% | 96.6% |
| 0.50 | 68.9% | 87.2% | 96.3% |
研究意义
仅使用一次筛查中的年龄、性别和屈光度的简单模型,即可预测哪些儿童会在一至三年内发展为高度近视;筛查设备的生物学测量值并不能进一步提升预测效果。
局限性: 数据来自中国一家医院的儿科,仅经过内部验证(交叉验证和时间划分验证),没有独立的外部队列;每个时间测试集仅含 14 个事件。此处的高度近视指等效球镜 −3.00 D 或更差,这是一个早期威胁视力的发展轨迹终点,而非常规的 −6.00 D 标准。
数据与再利用
所有数值均摘自已录用稿件(Article in Press,以 CC BY-NC-ND 4.0 开放获取)的表 1–7。 所有数值均可下载为整洁格式 CSV(每行一个测量值)或 JSON。图表与数据遵循文章的许可协议(CC BY-NC-ND 4.0):使用时须注明出处,且仅限非商业用途,且不得修改。完整方法请参阅原文。
全部已发表结果表(7 张)
表格按原文以英文显示。
| Screening year | Records | Male (%) | Female (%) | Age, mean (years) | Age, SD (years) | Age, min (years) | Age, max (years) |
|---|---|---|---|---|---|---|---|
| 2018 | 1742 | 51.1 | 48.9 | 8.7 | 1.8 | 6 | 13 |
| 2019 | 1274 | 50.9 | 49.1 | 8 | 1.7 | 6 | 13 |
| 2020 | 238 | 53.4 | 46.6 | 7.8 | 0.6 | 7 | 9 |
| 2021 | 2292 | 50.7 | 49.3 | 8.6 | 1.7 | 6 | 13 |
| Total | 5546 | 51 | 49 | 8.5 | 1.7 | 6 | 13 |
| Outcome | Records (n) | Patients | Event rate (%) | Endpoint |
|---|---|---|---|---|
| 1-year high myopia | 1039 | 1012 | 5.5 | SE ≤ −3.00D within 1 year |
| 2-year high myopia | 1559 | 1366 | 9.7 | SE ≤ −3.00D within 2 years |
| 3-year high myopia | 1781 | 1425 | 15.2 | SE ≤ −3.00D within 3 years |
| Mild-to-moderate prog. | 342 | 297 | 36.3 | SE ≤ −3.00D at next visit (mild myopic at baseline) |
| Onset | 1439 | 1325 | 33.2 | SE ≤ −0.50D at next visit (non-myopic at baseline) |
| Rapid progression | 408 | 365 | 70.3 | Rate ≤ −0.50D/year (myopic at baseline) |
| Variable | Overall (n = 1,559): mean | Overall (n = 1,559): SD | Events (n = 151): mean | Events (n = 151): SD | Non-events (n = 1,408): mean | Non-events (n = 1,408): SD |
|---|---|---|---|---|---|---|
| Age (years) | 7.8 | 1.2 | 8.3 | 1.2 | 7.7 | 1.2 |
| Male, n | 792 | – | 73 | – | 719 | – |
| Male, % | 50.8 | – | 48.3 | – | 51.1 | – |
| SE OD (D) | -0.05 | 0.78 | -1.15 | 0.75 | 0.06 | 0.72 |
| SE OS (D) | -0.04 | 0.79 | -1.17 | 0.79 | 0.08 | 0.73 |
| DC OD (D) | -0.68 | 0.61 | -0.84 | 0.63 | -0.67 | 0.61 |
| Anisometropia (D) | 0.31 | 0.44 | 0.46 | 0.58 | 0.3 | 0.42 |
| Pupil OD (mm) | 5.91 | 0.87 | 6.02 | 0.81 | 5.9 | 0.88 |
| Interpupil distance (mm) | 56.7 | 3.8 | 57.3 | 3.6 | 56.6 | 3.8 |
| Outcome | T1: Demographics AUC | T1: Demographics 95% CI lower | T1: Demographics 95% CI upper | T2: + Clinical refraction AUC | T2: + Clinical refraction 95% CI lower | T2: + Clinical refraction 95% CI upper | T3: + Power vectors AUC | T3: + Power vectors 95% CI lower | T3: + Power vectors 95% CI upper | T4: + Biometric AUC | T4: + Biometric 95% CI lower | T4: + Biometric 95% CI upper |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1-year high myopia | 0.688 | 0.62 | 0.751 | 0.878 | 0.815 | 0.931 | 0.862 | 0.798 | 0.918 | 0.849 | 0.782 | 0.909 |
| 2-year high myopia | 0.635 | 0.587 | 0.68 | 0.828 | 0.783 | 0.869 | 0.824 | 0.78 | 0.866 | 0.816 | 0.771 | 0.859 |
| 3-year high myopia | 0.598 | 0.562 | 0.636 | 0.795 | 0.761 | 0.827 | 0.786 | 0.75 | 0.821 | 0.791 | 0.758 | 0.824 |
| Mild-to-moderate | 0.495 | 0.436 | 0.556 | 0.782 | 0.733 | 0.829 | 0.764 | 0.711 | 0.813 | 0.755 | 0.701 | 0.806 |
| Onset | 0.628 | 0.597 | 0.656 | 0.739 | 0.714 | 0.764 | 0.732 | 0.706 | 0.758 | 0.733 | 0.707 | 0.759 |
| Rapid progression | 0.549 | 0.482 | 0.611 | 0.566 | 0.503 | 0.633 | 0.587 | 0.522 | 0.648 | 0.617 | 0.556 | 0.677 |
| Method | Features | AUC | AUC 95% CI lower | AUC 95% CI upper | Δ vs T2 | P(Δ > 0) | DeLong p |
|---|---|---|---|---|---|---|---|
| Clinical threshold rule | age, SE | 0.838 | 0.798 | 0.876 | 0.01 | 0.974 | – |
| Lin et al. 2018 (Random Forest) | age, SE, prog. rate | 0.794 | 0.745 | 0.84 | -0.034 | 0.014 | 0.022 |
| Random Forest | T4 full | 0.813 | 0.767 | 0.854 | -0.015 | 0.122 | – |
| XGBoost | T4 full | 0.779 | 0.731 | 0.826 | -0.049 | 0 | – |
| LightGBM | T4 full | 0.774 | 0.725 | 0.821 | -0.054 | 0.001 | – |
| Proposed T2 (ours) | age, sex, SE | 0.828 | 0.783 | 0.869 | – | – | – |
| Proposed T4 (+ biometric) | age, sex, SE, DC, biometric | 0.816 | 0.771 | 0.859 | -0.012 | 0.145 | 0.238 |
| Threshold | Sensitivity | Specificity | PPV | NPV | TP | FP | TN | FN |
|---|---|---|---|---|---|---|---|---|
| 0.05 | 0.993 | 0.021 | 0.098 | 0.967 | 150 | 1379 | 29 | 1 |
| 0.10 | 0.987 | 0.053 | 0.101 | 0.974 | 149 | 1333 | 75 | 2 |
| 0.15 | 0.96 | 0.129 | 0.106 | 0.968 | 145 | 1227 | 181 | 6 |
| 0.20 | 0.94 | 0.257 | 0.12 | 0.976 | 142 | 1046 | 362 | 9 |
| 0.25 | 0.868 | 0.429 | 0.14 | 0.968 | 131 | 804 | 604 | 20 |
| 0.30 | 0.834 | 0.585 | 0.177 | 0.971 | 126 | 584 | 824 | 25 |
| 0.40 | 0.742 | 0.786 | 0.271 | 0.966 | 112 | 301 | 1107 | 39 |
| 0.50 | 0.689 | 0.872 | 0.366 | 0.963 | 104 | 180 | 1228 | 47 |
| Horizon | Train n | Test n | Test events | T2 AUC | T2 95% CI lower | T2 95% CI upper | T4 AUC | T4 95% CI lower | T4 95% CI upper |
|---|---|---|---|---|---|---|---|---|---|
| 1-year high myopia | 838 | 201 | 14 | 0.814 | 0.661 | 0.925 | 0.799 | 0.641 | 0.914 |
| 2-year high myopia | 1358 | 201 | 14 | 0.804 | 0.648 | 0.922 | 0.803 | 0.667 | 0.914 |
| 3-year high myopia | 1580 | 201 | 14 | 0.796 | 0.633 | 0.92 | 0.802 | 0.654 | 0.92 |
获取全文
引用格式
显示 BibTeX
@article{wei2026predicting,
title = {{Predicting pediatric myopia progression from single screening encounters: a multi-outcome development and validation study}},
author = {Wei, Nan and Li, Chaoran and Moutari, Salissou and Usama, Muhammad and Li, Jing and Chen, Qiaoyan and Pazo, Emmanuel Eric and Qian, Xuehan},
journal = {Journal of Translational Medicine},
year = {2026},
doi = {10.1186/s12967-026-09003-2},
url = {https://doi.org/10.1186/s12967-026-09003-2},
}