角膜厚度对眼前节扫频源 OCT 测量的全角膜曲率所得手术源性角膜散光的影响
原文标题: The Influence of Corneal Thickness on Surgically Induced Corneal Astigmatism Derived from Total Keratometry Measured by Anterior Segment Swept-Source OCT
Fangyu Zhao, Yufan Yin, Emmanuel Eric Pazo, Fang Tian, Yuanfeng Jiang, Shaochong Bu
要点速览
在 2.2 mm 白内障切口术后,周边角膜越厚,手术源性散光越小。
- 研究设计
- 观察性研究
- 样本
- 71 只眼
- 平均 CSIA,前表面 K(D)
- 0.58
- 平均 CSIA,全角膜 K(D)
- 0.65
摘要
本研究旨在探讨眼前节扫频源光学相干断层扫描(AS-SS-OCT)测得的眼前节参数与由 AS-SS-OCT 测量的全角膜曲率(TK)计算所得的手术源性角膜散光(CSIA)之间可能存在的相关性。研究纳入了 67 名年龄相关性白内障患者的 71 只眼,均接受 2.2 mm 切口的超声乳化联合人工晶状体植入术。分别根据 AS-SS-OCT 测得的前表面角膜曲率(CSIA Kant )和 TK(CSIA TK )计算 CSIA 值。采用 Hotelling T 2 检验评估差异。采用 Spearman 相关系数检验 CSIA 与 AS-SS-OCT 所得各参数之间的相关性。CSIA Kant 和 CSIA TK 的质心分别为 0.31 ± 0.55 D @ 54° 和 0.41 ± 0.59 D @ 51°,差异无统计学意义( F = 1.283,p = 0.281,Hotelling T 2 )。CSIA Kant 和 CSIA TK 的平均绝对值分别为 0.58 ± 0.24 D 和 0.65 ± 0.28 D。Spearman 检验显示,CSIA Kant 的大小与术前周边角膜厚度(PCT,p = 0.045)及前表面角膜曲率的大小( p = 0.044)呈负相关。CSIA TK 的大小与术前中央角膜厚度(CCT,p = 0.003)及术前 PCT( p = 0.015)呈负相关。周边角膜厚度增加与 CSIA 大小减小相关。我们发现的角膜厚度与 CSIA 之间的相关性表明,在预测 CSIA 时应考虑某些术前参数,以获得更精确的屈光结果。
译自英文原文摘要(许可协议:CC BY-NC)。
显示英文原文摘要
The purpose of the study was to explore the possible correlations between the anterior segment parameters derived from anterior segment swept-source optical coherence tomography (AS-SS-OCT) with the surgically induced corneal astigmatism (CSIA) calculated from total keratometry (TK) measured by AS-SS-OCT. Seventy-one eyes of 67 patients with age-related cataract who underwent phacoemulsification combined with intraocular lens implantation with 2.2-mm incision were included. The CSIA values were calculated from anterior keratometry (CSIA Kant ) and TK (CSIA TK ) measured by AS-SS-OCT, respectively. Hotelling’s T 2 test was used to evaluate the difference. The correlation of CSIA with various parameters derived from AS-SS-OCT was tested with the Spearman correlation coefficient. The centroid of CSIA Kant and of CSIA TK were 0.31 ± 0.55 D @ 54° and 0.41 ± 0.59 D @ 51°, with no significant difference ( F = 1.283, p = 0.281, Hotelling’s T 2 ). The mean absolute CSIA Kant and CSIA TK were 0.58 ± 0.24 D and 0.65 ± 0.28 D. Spearman test showed that the magnitude of CSIA Kant was negatively correlated with preoperative peripheral corneal thickness (PCT, p = 0.045) and the magnitude of anterior keratometry ( p = 0.044). The magnitude of CSIA TK was negatively correlated with preoperative central corneal thickness (CCT, p = 0.003) and preoperative PCT ( p = 0.015). The increased thickness of the peripheral cornea is correlated with the decrease in the magnitude of the CSIA. The correlation we identified between the corneal thickness and the CSIA indicated that certain preoperative parameters should be considered for the prediction of CSIA for a more precise refractive outcome.
关键词: corneal thickness; central corneal thickness; peripheral corneal thickness; total keratometry; phacoemulsification; intraocular lens implantation; senile cataract; refractive outcome prediction
获取全文
引用格式
显示 BibTeX
@article{zhao2024the,
title = {{The Influence of Corneal Thickness on Surgically Induced Corneal Astigmatism Derived from Total Keratometry Measured by Anterior Segment Swept-Source OCT}},
author = {Zhao, Fangyu and Yin, Yufan and Pazo, Emmanuel Eric and Tian, Fang and Jiang, Yuanfeng and Bu, Shaochong},
journal = {Ophthalmology and Therapy},
year = {2024},
doi = {10.1007/s40123-024-00996-x},
url = {https://doi.org/10.1007/s40123-024-00996-x},
}