简体中文

← 论文

巩膜接触镜对角膜规则的近视患者的益处:一项前瞻性随机研究

原文标题: Scleral Contact Lens Benefits for Myopic Patients With Regular Corneas: A Prospective Randomized Study

Ruixue Liang, Na Li, Lin Liu, Bei Du, Emmanuel Eric Pazo, Ruihua Wei

Eye & Contact Lens Science & Clinical Practice, 2024 · 期刊论文 · doi:10.1097/icl.0000000000001151

近视与屈光不正眼表与干眼

图文摘要. 随机对照试验 · 80 名近视患者. 配戴时间: 3 months. 与角膜硬性接触镜相比,巩膜镜为角膜规则的近视患者带来了更好的光学质量和更稳定的泪膜。
图文摘要: SVG · PNG · JSON · 可在注明出处的前提下自由使用(CC BY 4.0)

要点速览

与角膜硬性接触镜相比,巩膜镜为角膜规则的近视患者带来了更好的光学质量和更稳定的泪膜。

研究设计
随机对照试验
样本
80 名近视患者
配戴时间
3 months

摘要

本文摘要以原文(英文)显示,因为该文章未采用允许翻译的开放许可协议。

OBJECTIVES: To evaluate the impact of scleral contact lens (SL) wear on the visual quality and the ocular surface wettability in myopic patients with regular corneas. METHODS: This prospective, randomized, controlled study enrolled a total of 80 myopes with regular corneas. Subjects were randomly allocated to wear SL or rigid corneal lens (RCL) for 3 months. The objective optical quality parameters were detected using the Optical Quality Analysis System-II, and the ocular surface wettability was assessed using the Keratograph 5M noninvasive ocular surface analyzer. The National Eye Institute 25-Item Visual Function Questionnaire and Ocular Surface Disease Index questionnaire were performed. RESULTS: Both SL and RCL wear could obtain good best-corrected visual acuity. Strehl ratio, modulation transfer function cutoff frequency, objective scattering index, and Optical Quality Analysis System values (Optical Quality Analysis System values at 100%, 20%, and 9% contrasts) in the SL group significantly improved from baseline to the third month (both P <0.05), but not in the RCL group. At the third month, tear meniscus height and noninvasive tear break-up time showed a significant increase in the SL wearers from baseline (both P <0.05), but exhibited no significant changes in the RCL group. At the third month, SL wearers had significantly higher noninvasive tear break-up time compared with RCL wearers ( P <0.05). Besides, after 3-month SL wear, the National Eye Institute 25-Item Visual Function Questionnaire score and the Ocular Surface Disease Index score both remarkably improved from baseline (both P <0.05). CONCLUSION: Short-term SL wear could provide satisfactory visual quality, ocular comfort, and stable tear film for myopic patients.

关键词: scleral lenses; myopia; visual quality; optical quality; tear film stability; tear film break-up time; tear meniscus height; ocular comfort

获取全文

引用格式

Liang, R., Li, N., Liu, L., Du, B., Pazo, E. E., Wei, R. (2024). Scleral Contact Lens Benefits for Myopic Patients With Regular Corneas: A Prospective Randomized Study. Eye & Contact Lens Science & Clinical Practice. https://doi.org/10.1097/icl.0000000000001151

显示 BibTeX
@article{liang2024scleral,
  title = {{Scleral Contact Lens Benefits for Myopic Patients With Regular Corneas: A Prospective Randomized Study}},
  author = {Liang, Ruixue and Li, Na and Liu, Lin and Du, Bei and Pazo, Emmanuel Eric and Wei, Ruihua},
  journal = {Eye & Contact Lens Science & Clinical Practice},
  year = {2024},
  doi = {10.1097/icl.0000000000001151},
  url = {https://doi.org/10.1097/icl.0000000000001151},
}

相关研究