Qing Zhang, Yi Wu, Yilin Song, Guanghao Qin, Lanting Yang, Sumeet Singh Talwar, Tiezhu Lin, Gagan Deep Singh Talwar, Hongda Zhang, Ling Xu, Jonathan Edward Moore, Emmanuel Eric Pazo, Wei He
要点速览
智能手机热成像相机可无接触地快速筛查蒸发过强型干眼。
- 研究设计
- 观察性病例对照研究
- 样本
- 184 只眼
- AUC(鼻侧角膜缘温度)
- 0.79
- 灵敏度
- 0.96
- 特异度
- 0.91
摘要
背景。干眼(DED)是一种多因素疾病,也是眼科门诊最常见的问题之一。由于临床表现多样,DED 的诊断需结合多项主观和客观临床检查。本研究旨在评估一种基于智能手机的手持式红外热成像(IRT)相机筛查症状性蒸发过强型 DED 的有效性。方法。这项性别匹配的观察性对照研究评估了 184 名参与者 184 只右眼(正常 46 只,DED 138 只)的 IRT 图像。采用非侵入性泪膜破裂时间、荧光素染色和中文版眼表疾病指数(C‐OSDI)问卷评估蒸发过强型 DED,并将其归入相应的干眼症状组(无、轻度、中度或重度)。使用基于智能手机的手持式 IRT 相机测量并比较 8 个解剖感兴趣区(ROI)(鼻侧结膜、鼻侧角膜缘、鼻侧角膜、中央角膜、下方角膜、颞侧角膜缘、颞侧角膜和颞侧结膜)的眼表温度(OST)。通过与 DED 严重程度的相关性及曲线下面积(AUC)评估这 8 个 ROI 的 OST 检测不同严重程度 DED 的有效性。结果。除下方角膜、颞侧角膜缘和颞侧结膜区域外(>0.05),DED 参与者 8 个解剖 ROI 的 OST 均显著高于非 DED 组( p < 0.05)。对 8 个解剖 ROI 的分析显示,鼻侧角膜缘与 DED 严重程度的 Pearson 相关性最高(0.64,p < 0.001)。此外,在区分 DED 眼与非 DED 眼时,鼻侧角膜缘 ROI 的 AUC 最高,为 0.79(CI:0.73–0.85;p < 0.05),灵敏度和特异度也最高(0.96 和 0.91)。结论。基于智能手机的手持式 IRT 图像不宜作为诊断工具,但可作为区分 DED 与非 DED 的快速、非侵入性且卫生的筛查工具,并有望减轻常规检查带来的不适。
译自英文原文摘要(许可协议:CC BY)。
显示英文原文摘要
Background . Dry eye disease (DED) is a multifactorial and one of the most common problems treated in an ophthalmic outpatient clinic. Due to the variability in presentation, diagnosis of DED consists of a combination of subjective and objective clinical tests. The purpose of this study was to assess the effectiveness of a handheld smartphone‐based infrared thermal (IRT) camera for screening symptomatic evaporative DED. Methods . This observational sex‐matched control study assessed IRT images of 184 right eyes (46 normal and 138 DED) of 184 participants. Evaporative DED was assessed using noninvasive tear breakup time, fluorescein staining, and the Chinese version of the ocular surface disease index (C‐OSDI) questionnaire and categorized into their respective dry eye symptomology group (none, mild, moderate, or severe). The ocular surface temperature (OST) at 8 anatomical regions of interest (ROI) (nasal conjunctiva, nasal limbus, nasal cornea, central cornea, inferior cornea, temporal limbus, temporal cornea, and temporal conjunctiva) were measured and compared using a handheld smartphone‐based IRT camera. The effectiveness of these 8 ROIs OST in detecting varying severity of DED was evaluated in terms of correlations with severity of DED and their area under the curve (AUC). Results . OST at the 8 anatomical ROI was significantly higher in DED participants than in the non‐DED group ( p < 0.05) except for inferior cornea, temporal limbus, and temporal conjunctival regions (>0.05). Analyzing 8 anatomical ROIs revealed that the nasal limbus had the highest Pearson correlation with the severity of DED (0.64, p < 0.001). Additionally, the nasal limbus ROI achieved the highest AUC of 0.79 (CI: 0.73–0.85; p < 0.05), sensitivity, and specificity (0.96 and 0.91) when comparing its ability to discriminated DED vs. non‐DED eyes. Conclusions . Rather than a diagnostic tool, handheld smartphone‐based IRT images can be considered as a rapid, noninvasive, and hygienic screening tool in discriminating DED and non‐DED and potentially alleviating inconvenience experienced during conventional tests.
关键词: evaporative dry eye disease; infrared thermography; ocular surface temperature; tear film break-up time; fluorescein staining; Ocular Surface Disease Index; non-invasive diagnosis
获取全文
引用格式
显示 BibTeX
@article{zhang2021screening,
title = {{Screening Evaporative Dry Eyes Severity Using an Infrared Image}},
author = {Zhang, Qing and Wu, Yi and Song, Yilin and Qin, Guanghao and Yang, Lanting and Talwar, Sumeet Singh and Lin, Tiezhu and Talwar, Gagan Deep Singh and Zhang, Hongda and Xu, Ling and Moore, Jonathan Edward and Pazo, Emmanuel Eric and He, Wei},
journal = {Journal of Ophthalmology},
year = {2021},
doi = {10.1155/2021/8396503},
url = {https://doi.org/10.1155/2021/8396503},
}
相关研究
- 飞秒激光辅助 LASIK 术后角膜瓣边缘间隙对角膜神经再生影响的分析 (2026)
- 强脉冲光与睑缘清洁对泪膜和眼表影响的比较:一项随机对照研究 (2026)
- Effects of 3% diquafosol sodium on tear film stability, corneal aberration parameters, and vision-related quality of life in pediatric orthokeratology-associated dry eye disease (2026)
- 母亲孕前体重指数与子代散光及角膜曲率的关联:一项横断面研究 (2025)
- 过敏性结膜炎相关干眼中泪液淋巴毒素-α、免疫球蛋白 E 及基质金属蛋白酶-9 的差异表达 (2025)