简体中文

← 论文

旋转非对称多焦点人工晶状体

原文标题: Rotationally asymmetric multifocal intraocular lenses: preoperative considerations and postoperative outcomes

Jonathan Edward Moore, Richard N. McNeely, Emmanuel Eric Pazo, Tara Moore

Current Opinion in Ophthalmology, 2016 · 综述 · doi:10.1097/icu.0000000000000339 · 被引 35 次

白内障与眼前节手术

图文摘要. 综述 · 已发表的研究. 在患者选择得当时,非对称多焦点人工晶状体可在各距离提供良好视力,且光学干扰现象少。
图文摘要: SVG · PNG · JSON · 可在注明出处的前提下自由使用(CC BY 4.0)

要点速览

在患者选择得当时,非对称多焦点人工晶状体可在各距离提供良好视力,且光学干扰现象少。

研究设计
综述
样本
已发表的研究

摘要

本文摘要以原文(英文)显示,因为该文章未采用允许翻译的开放许可协议。

PURPOSE OF REVIEW: The manuscript presents a review of recently published studies reporting objective and subjective outcomes and preoperative considerations of asymmetrical multifocal intraocular lenses (IOLs). RECENT FINDINGS: Current publications suggest that asymmetrical multifocal IOLs provide good, distance, intermediate and near vision for cataract and clear lens extraction patients. The contrast sensitivity achieved is similar to monofocal IOLs. Photopic phenomenon such as glare and halos has been reduced through the use of these IOLs leading to better patient satisfaction. Centration plays a critical role and the lack of a gold standard assessment tool has led to a minority of patients experiencing lower quality of vision and side-effects such as glare and hazy vision. The frequency of dissatisfied patients can be minimized by appropriate patient selection. This is achieved by assessing pupil parameters which guides the surgeon to align the IOL accordingly. SUMMARY: Asymmetric multifocal IOLs provide the surgeon with an IOL that achieves excellent visual and refractive outcomes enabling patients to see clearly at a range of distances. Subjectively patients report low levels of photopic phenomena and high levels of spectacle independence resulting in high overall patient satisfaction.

关键词: cataract surgery; clear lens extraction; IOL centration; glare and halos; contrast sensitivity; patient satisfaction; spectacle independence; patient selection

获取全文

引用格式

Moore, J. E., McNeely, R. N., Pazo, E. E., Moore, T. (2016). Rotationally asymmetric multifocal intraocular lenses: preoperative considerations and postoperative outcomes. Current Opinion in Ophthalmology. https://doi.org/10.1097/icu.0000000000000339

显示 BibTeX
@article{moore2016rotationally,
  title = {{Rotationally asymmetric multifocal intraocular lenses: preoperative considerations and postoperative outcomes}},
  author = {Moore, Jonathan Edward and McNeely, Richard N. and Pazo, Emmanuel Eric and Moore, Tara},
  journal = {Current Opinion in Ophthalmology},
  year = {2016},
  doi = {10.1097/icu.0000000000000339},
  url = {https://doi.org/10.1097/icu.0000000000000339},
}

相关研究