Función macular medida con el microperímetro Nidek MP-3 en personas chinas sanas de distintos grupos de edad
Título original: Macular function measured by Nidek MP-3 microperimeter in normal Chinese individuals across age groups
Dan Hu, Qiuhai Wang, Qingcui Liu, Emmanuel Eric Pazo, Zhe Liu, Shuang Wu, Wen Zhang, Xing Yan, Bo Yu
De un vistazo
La sensibilidad macular y la estabilidad de la fijación medidas con el MP-3 disminuyen con la edad en ojos sanos.
- Diseño
- Estudio normativo transversal
- Muestra
- 182 ojos sanos
- Sensibilidad macular media (dB)
- 29.5
- % de puntos de fijación dentro de 2°
- 93.0
- % de puntos de fijación dentro de 4°
- 98.3
Resumen
Antecedentes: En los últimos años, la microperimetría se ha consolidado como herramienta para evaluar la función retiniana, en especial la función macular. En este estudio se empleó el MP-3, un dispositivo ampliamente adoptado, para analizar la sensibilidad macular y la estabilidad de la fijación en distintos grupos de edad. Métodos: La investigación evaluó la sensibilidad macular y la estabilidad de la fijación de 182 ojos sanos sin trastornos oculares. La relación entre la sensibilidad macular, el patrón de fijación y la edad se determinó mediante ecuaciones de estimación generalizadas. Resultados: Se midieron con el MP-3 la sensibilidad macular y el porcentaje de estabilidad de la fijación dentro de 2° y 4° en 182 ojos (edad media: 45.24 ± 17.03 años). La sensibilidad macular media fue de 29.5 ± 1.6, mientras que el porcentaje medio de puntos de fijación dentro de un círculo de 2° fue del 93.0 ± 7.5% y dentro de un círculo de 4°, del 98.3 ± 2.8%. La sensibilidad macular, así como el porcentaje de puntos de fijación dentro de las áreas centrales de 2° y 4°, tendieron a disminuir con la edad. Conclusión: En conclusión, en sujetos normales, la sensibilidad macular y los valores de fijación disminuyen con la edad. El MP-3 resulta un instrumento fiable para medir la función macular.
Traducido del resumen original en inglés (licencia: CC BY).
Mostrar el resumen original
Background: Microperimetry has emerged as a tool for assessing retinal function, especially macular function in recent years. In this study, the MP-3, a widely adopted device, was employed to analyze macular sensitivity and fixation stability across various age groups. Methods: The research involved evaluating the macular sensitivity and fixation stability of 182 healthy eyes free from ocular disorders. The relationship between macular sensitivity, fixation pattern, and age was determined through generalized estimating equations. Results: Macular sensitivity and percentage of fixation stability within 2° and 4° were measured for 182 eyes (mean age: 45.24 ± 17.03 years) using MP-3. The mean macular sensitivity was 29.5 ± 1.6, while the mean percentage of fixation points within a 2° circle was 93.0 ± 7.5%, and within a 4° circle was 98.3 ± 2.8%. Macular sensitivity, as well as the percentage of fixation points within the central 2° and 4° areas, tended diminish with advancing age. Conclusion: In conclusion, among normal subjects, macular sensitivity and fixation values decrease with age. MP-3 emerges as a reliable instrument for measuring macular function.
Palabras clave: macular function; microperimetry; macular sensitivity; fixation stability; age-related decline; retinal function; healthy eyes; Chinese population
Acceso
Cómo citar
Mostrar BibTeX
@article{hu2025macular,
title = {{Macular function measured by Nidek MP-3 microperimeter in normal Chinese individuals across age groups}},
author = {Hu, Dan and Wang, Qiuhai and Liu, Qingcui and Pazo, Emmanuel Eric and Liu, Zhe and Wu, Shuang and Zhang, Wen and Yan, Xing and Yu, Bo},
journal = {PeerJ},
year = {2025},
doi = {10.7717/peerj.19961},
url = {https://doi.org/10.7717/peerj.19961},
}
Trabajos relacionados
- Asociación entre la presión de perfusión ocular media y la retinopatía diabética proliferativa en una población del norte de China (2026)
- Asociación de los conocimientos y actitudes sobre el tratamiento anti-VEGF con la interrupción autodeclarada del tratamiento: un estudio de clasificación con separación temporal (2026)
- Medición automatizada basada en aprendizaje profundo del volumen de retinosquisis y desprendimiento en la miopía patológica con contracción escleral posterior (2026)
- Desarrollo de un modelo predictivo basado en datos de citocinas del humor acuoso para la respuesta al tratamiento anti-VEGF en el edema macular diabético (2026)
- Repetibilidad de las métricas de fotorreceptores de tipo cono con una oftalmoscopia láser de barrido con óptica adaptativa comercial (Mona II) en adultos sanos (2026)