Optos 超广角扫描激光检眼镜评估视力损害性飞蚊症
原文标题: Vision degrading myodesopsia assessed with optos ultra-widefield scanning laser ophthalmoscope
Tiezhu Lin, Cheng Shi, Bing Heng Wu, Emmanuel Eric Pazo, Lijun Shen
要点速览
Optos 广角成像会漏掉大多数玻璃体漂浮物,尤其是在没有玻璃体后脱离的眼中。
- 研究设计
- 横断面研究
- 样本
- 420 只眼
- Optos 上可见漂浮物的比例
- 47.62%
- 无 PVD 眼中可见的比例
- 15%
- 伴有其他视网膜异常的比例
- 25.71%
摘要
背景:探讨 Optos 成像对视力损害性飞蚊症(VDM)的诊断灵敏度。方法:这项横断面研究共收集了 345 名 VDM 患者的 420 只眼。所有眼均分为有玻璃体后脱离(PVD)和无 PVD 两类。评估 Optos 成像显示玻璃体漂浮物的灵敏度。采用单因素和多因素 Logistic 回归分析与 Optos 图像上玻璃体漂浮物可见性相关的因素。结果:所有患者的平均年龄为 56.19 ± 13.89 岁,66.67% 为女性。所有眼的 B 超均可见玻璃体漂浮物,但仅 47.62% 的 Optos 图像可见(有 PVD 的眼中为 55.29%,无 PVD 的眼中为 15%)。在多因素二元 Logistic 回归分析中,年龄(OR = 1.094,95%CI = 1.063-1.125,P < 0.001)、等效球镜度(OR = 0.869,95%CI = 0.791-0.955,P = 0.004)以及漂浮物与视网膜的距离(OR = 1.191,95%CI = 1.059-1.339,P = 0.003)与 Optos 图像上玻璃体漂浮物的可见性显著相关。在 Optos 图像上,25.71% 的 VDM 眼存在其他视网膜异常。结论:Optos 成像对玻璃体漂浮物的灵敏度较低,在无 PVD 的眼中尤为明显。在 Optos 成像上,年龄较大的患者、近视程度较高的眼以及距视网膜较远的漂浮物更容易被看到。
译自英文原文摘要(许可协议:CC BY)。
显示英文原文摘要
BACKGROUND: To investigate the diagnostic sensitivity of Optos imaging for vision degrading myodesopsia (VDM). METHODS: A total of 420 eyes from 345 patients with VDM were collected in this cross-sectional study. All eyes were classified as having posterior vitreous detachment (PVD) or not having PVD. The sensitivity of Optos imaging for the visibility of vitreous floaters was evaluated. The associated factors with the visibility of vitreous floaters on Optos images were analyzed in univariate and multivariate logistic regression analyses. RESULTS: The mean age of all patients was 56.19 ± 13.89 years old, and 66.67% of patients were female. The vitreous floaters were visible on the ultrasound B scan in all eyes, but only in 47.62% of Optos images (55.29% in eyes with PVD and 15% in eyes without PVD). In the multiple binary logistic regression analysis, age (OR = 1.094, 95%CI = 1.063-1.125, P < 0.001), spherical equivalent (OR = 0.869, 95%CI = 0.791-0.955, P = 0.004) and the distance of the floaters from the retina (OR = 1.191, 95%CI = 1.059-1.339, P = 0.003) were significantly correlated with the visibility of vitreous floaters on Optos images. On Optos images, 25.71% of VDM eyes presented additional retinal abnormalities. CONCLUSIONS: Optos imaging has a low sensitivity for vitreous floaters, particularly in eyes without PVD. On Optos imaging, floaters were more visible in older patients, eyes with greater myopia, and floaters that were further from the retina.
关键词: vitreous floaters; posterior vitreous detachment; diagnostic sensitivity; myopia; retinal abnormalities
获取全文
引用格式
显示 BibTeX
@article{lin2023vision,
title = {{Vision degrading myodesopsia assessed with optos ultra-widefield scanning laser ophthalmoscope}},
author = {Lin, Tiezhu and Shi, Cheng and Wu, Bing Heng and Pazo, Emmanuel Eric and Shen, Lijun},
journal = {BMC Ophthalmology},
year = {2023},
doi = {10.1186/s12886-023-03166-y},
url = {https://doi.org/10.1186/s12886-023-03166-y},
}