角膜直径对中国患者角膜生物力学及生物测量参数的影响:一项横断面研究
原文标题: Influence of Corneal Diameter on Corneal Biomechanics and Biometry in Chinese Patients: A Cross-Sectional Study
Huanmin Cheng, Qiwei Li, Fan Yang, Emmanuel Eric Pazo, Jonathan Edward Moore, Zhanglin Liu, Ming Sun, Shaozhen Zhao, Yue Huang
要点速览
角膜直径会改变 Pentacam 和 Corvis ST 指标,因此在圆锥角膜筛查中应予以考虑。
- 研究设计
- 横断面研究
- 样本
- 203 只眼
- 小角膜阈值
- 11.1 mm
摘要
本文摘要以原文(英文)显示,因为该文章的许可协议(CC BY-NC-ND)不允许发布译文。
Purpose: The purpose of this study was to investigate the influence of corneal diameter (CD) on corneal biomechanics and biometry parameters to allow more accurate evaluation of refractive surgery patients. Methods: In this cross-sectional study, 203 Chinese participants were categorized into four groups based on CD (group A = CD ≤11.1 mm, group B = CD = 11.2-11.5 mm, group C = CD = 11.6-12 mm, and group D = CD >12.0 mm). Data collected included age, gender, intraocular pressure, spherical equivalent, and parameters from the Pentacam and Corvis ST. Statistical analysis was performed using SPSS software. Results: The study included 203 eyes. For the Pentacam examination, corneal curvature, thinnest pachymetry (TP), back elevations (BEs), corneal elevation difference (front and back), pachymetry progression indices (PPIs), index of surface variance (ISV), keratoconus percentage index (KISA%), and most of the Belin/Ambrósio Enhanced Ectasia Display (BAD) parameters were negatively correlated with CD (linear regression analysis, P < 0.05). The abnormal rate of Pentacam parameters in the CD ≤11.1 mm group was higher than other groups. For Corvis ST, CD was positively correlated with peak distance (PD) and Ambrósio relational thickness to the horizontal profile (Arth), but negatively correlated with tomographic and biomechanical index (TBI) and Corvis biomechanical index (CBI; linear regression analysis, P < 0.05). The CD ≤11.1 mm group demonstrated the highest CBI and TBI values, although these parameters remained within the normal range. Conclusions: Corneal diameter significantly influences Pentacam and Corvis ST parameters, particularly on BE, BAD-D, PPIs, CBI, and TBI. Translational Relevance: Incorporating corneal diameter into preoperative screening may help improve the specificity of keratoconus detection and reduce unnecessary exclusion of eligible refractive surgery candidates with small corneas.
关键词: corneal diameter; corneal biomechanics; corneal biometry; keratoconus; refractive surgery candidates; Pentacam; Corvis ST; Corvis Biomechanical Index
获取全文
引用格式
显示 BibTeX
@article{cheng2025influence,
title = {{Influence of Corneal Diameter on Corneal Biomechanics and Biometry in Chinese Patients: A Cross-Sectional Study}},
author = {Cheng, Huanmin and Li, Qiwei and Yang, Fan and Pazo, Emmanuel Eric and Moore, Jonathan Edward and Liu, Zhanglin and Sun, Ming and Zhao, Shaozhen and Huang, Yue},
journal = {Translational Vision Science & Technology},
year = {2025},
doi = {10.1167/tvst.14.11.34},
url = {https://doi.org/10.1167/tvst.14.11.34},
}
相关研究
- 飞秒激光辅助 LASIK 术后角膜瓣边缘间隙对角膜神经再生影响的分析 (2026)
- 强脉冲光与睑缘清洁对泪膜和眼表影响的比较:一项随机对照研究 (2026)
- Effects of 3% diquafosol sodium on tear film stability, corneal aberration parameters, and vision-related quality of life in pediatric orthokeratology-associated dry eye disease (2026)
- 母亲孕前体重指数与子代散光及角膜曲率的关联:一项横断面研究 (2025)
- 过敏性结膜炎相关干眼中泪液淋巴毒素-α、免疫球蛋白 E 及基质金属蛋白酶-9 的差异表达 (2025)