 "title": "Optimized Visual Outcome After Asymmetrical Multifocal IOL Rotation",
 "url": "https://ericpazo.org/publications/2016-optimized-visual-outcome-after-asymmetrical-multifocal/",
 "doi": "10.3928/1081597x-20160503-01",
 "doi_url": "https://doi.org/10.3928/1081597x-20160503-01",
 "venue": "Journal of Refractive Surgery",
 "year": 2016,
 "authors": [
  "Emmanuel Eric Pazo",
  "Olivier Richoz",
  "Richard N. McNeely",
  "Zack Millar",
  "Tara Moore",
  "Jonathan Edward Moore"
 ],
 "topic": "Cataract & anterior segment surgery",
 "design": "Case report",
 "sample": "1 patient",
 "findings": [
  {
   "value": "120°",
   "label": "IOL rotation",
   "proportion": null
  },
  {
   "value": "-0.1 logMAR",
   "label": "UDVA after rotation",
   "proportion": null
  }
 ],
 "conclusion": "Rotating a decentred asymmetric multifocal IOL immediately improved vision and quality of vision.",
 "summary": "Case report of 1 patient. Key results: IOL rotation: 120°; UDVA after rotation: -0.1 logMAR. Conclusion: Rotating a decentred asymmetric multifocal IOL immediately improved vision and quality of vision.",
 "images": {
  "png": "https://ericpazo.org/publications/2016-optimized-visual-outcome-after-asymmetrical-multifocal/visual-abstract.png",
  "svg": "https://ericpazo.org/publications/2016-optimized-visual-outcome-after-asymmetrical-multifocal/visual-abstract.svg",
  "width": 1200,
  "height": 630
 },
 "license": "https://creativecommons.org/licenses/by/4.0/",
 "source_note": "Finding values are quoted verbatim from the published abstract."
}